9000 Series Mixer/Amplifiers RS-232C Protocol Manual Ver.3.
TABLE OF CONTENTS Page# 1. SUMMARY…………………………………………………………………….... 3 2. SERIAL PORT SETTING…………………………………………………….... 3 3. COMMAND CONFIGURATION………………………………………………. 4 4. TRANSMISSION DATA AFTER COMMAND RECEPTION……………….. 4 5. CONTROL COMMAND AND SETTING VALUE……………………………. 5 5.1. Channel Fader Gain……………………………………………………………. 5 5.1.1. Channel Fader Gain - Position setting…………………………………… 5 5.1.2 Channel Fader Gain - Step Up/ Step Down…………………………….…. 7 5.2. Crosspoint Gain………………………………………………………………… 9 5.3.
1. SUMMARY The RS-232C protocol described in this document is designed to be used to control the 9000 Series Amplifier from a PC and/or remote controller. This specification applies to the 9000 Series firmware version 3.10 or later.
3. COMMAND CONFIGURATION • • Command Data length (N) Data 1 Data 2 is in the range of 80H to FFH. Command range of 00H to 7FH. Data Data N and Data length are in the • Data length (N) refers to the length of the subsequent data of Data 1 to Data N. • If received data contains more byte data than the Data length, these exceeding data are abandoned. • If a next command received contains byte data shorter than the Data length, the previous command is abandoned. 4.
.1. Channel Fader Gain 5.1.1. Channel Fader Gain - Position setting Set the input and output channel fader gains to a fixed value position. Note: Command cannot be received during power off. 9000Series Amplifier responds with the same data as that received.
HEX Position DEC Gain (dB) HEX Position DEC Gain (dB) HEX DEC Position Gain (dB) HEX Position DEC Gain (dB) 00H 0 -∞ 22H 34 -36.0 44H 68 -19.0 66H 102 -2.0 01H 1 -70.0 23H 35 -35.5 45H 69 -18.5 67H 103 -1.5 02H 2 -68.0 24H 36 -35.0 46H 70 -18.0 68H 104 -1.0 03H 3 -66.0 25H 37 -34.5 47H 71 -17.5 69H 105 -0.5 04H 4 -64.0 26H 38 -34.0 48H 72 -17.0 6AH 106 0.0 05H 5 -62.0 27H 39 -33.5 49H 73 -16.5 6BH 107 +0.5 06H 6 -60.
5.1.2 Channel Fader Gain - Step Up/ Step Down Set the input and output channel gain positions by the number of steps. Positions can be varied from the current status by the designated number of steps. One position varies per step. 9000Series Amplifier responds with the same data as that received. The 9000series Amplifier informs position values changed by Step Up or Down.
CHANNEL FADER GAIN – STEP UP / STEP DOWN TABLE Step Up HEX DEC 41H 65 42H 66 43H Gain (dB) Step Down Gain (dB) HEX DEC +0.5 step 61H 97 -0.5 step +1.0 step 62H 98 -1.0 step 67 +1.5 step 63H 99 -1.5 step 44H 68 +2.0 step 64H 100 -2.0 step 45H 69 +2.5 step 65H 101 -2.5 step 46H 70 +3.0 step 66H 102 -3.0 step 47H 71 +3.5 step 67H 103 -3.5 step 48H 72 +4.0 step 68H 104 -4.0 step 49H 73 +4.5 step 69H 105 -4.5 step 4AH 74 +5.0 step 6AH 106 -5.
5.2. Crosspoint Gain Set the crosspoint switch gain. 9000Series Amplifier responds with the same data as that received. This command is enabled when in the mixer mode only. Note: Command cannot be received during power off.
CROSSPOINT GAIN TABLE value HEX DEC Gain (dB) Value HEX DEC Gain (dB) Value HEX DEC Gain (dB) Value HEX DEC Step Down 00H 0 -∞ 22H 34 -37.0 44H 68 -3.0 65H 101 -6.0 step 01H 1 -70.0 23H 35 -36.0 45H 69 -2.0 66H 102 -7.0 step 02H 2 -69.0 24H 36 -35.0 46H 70 -1.0 67H 103 -8.0 step 03H 3 -68.0 25H 37 -34.0 47H 71 0.0 68H 104 -9.0 step 04H 4 -67.0 26H 38 -33.0 48H 72 1.0 69H 105 -10.0 step 05H 5 -66.0 27H 39 -32.0 49H 73 2.
5.3. Preset Memory Recall Recalls any desired preset memories. 9000Series Amplifier responds with the same data as that received. Note: Settings to be stored in preset memories are referred to as “SCENE” in mixer mode and “EVENT” in matrix mode. In 'Matrix mode', the command of 'EVENT end' is not provided. Therefore, it is recommended to use ‘Preset memory recall’ command only for Mixer mode ‘SCENE’ activation.
5.4. Channel ON/OFF This performs ON/OFF setting of the Input or Output channel. 9000Series Amplifier responds with the same data as that received.
5.6. Tone Control Performs Bass and Treble gain settings of the input/output channels. 9000Series Amplifier responds with the same data as that received.. Note: Command cannot be received during power off.
TONE CONTROL GAIN POSITION TABLE Value HEX Gain (dB) DEC Value HEX DEC Gain (dB) 00H 0 -12.0 0DH 13 +1.0 01H 1 -11.0 0EH 14 +2.0 02H 2 -10.0 0FH 15 +3.0 03H 3 -9.0 10H 16 +4.0 04H 4 -8.0 11H 17 +5.0 05H 5 -7.0 12H 18 +6.0 06H 6 -6.0 13H 19 +7.0 07H 7 -5.0 14H 20 +8.0 08H 8 -4.0 15H 21 +9.0 09H 9 -3.0 16H 22 +10.0 0AH 10 -2.0 17H 23 +11.0 0BH 11 -1.0 18H 24 +12.
5.7. EQ Settings Perform EQ settings (ON/OFF, Band number, Gain, Q and Center frequency) of the input/output channels. 9000Series Amplifier responds with the same data as that received. Band number, Gain, Q, and Center frequency cannot be received when EQ is set to OFF. They can be valid only when EQ is set to ON. Note: Command cannot be received during power off.
EQ-Q TABLE Value Q HEX DEC 00H 0 0.3 01H 1 0.5 02H 2 0.7 03H 3 1 04H 4 1.5 05H 5 2 06H 6 3 07H 7 5 EQ-FREQUENCY TABLE Value Freq (Hz) HEX DEC 00H 0 01H Value Freq (Hz) HEX DEC 20 11H 13 1k 1 25 12H 14 1.25k 02H 2 31.5 13H 15 1.6k 03H 3 40 14H 16 2k 04H 4 50 15H 17 2.5k 05H 5 63 16H 18 3.15k 06H 6 80 17H 19 4k 07H 7 100 18H 20 5k 08H 8 125 19H 21 6.
5.8. Loudness Compensation Settings Perform loudness compensation settings of the Input / Output channels. 9000Series Amplifier responds with the same data as that received. Note: Command cannot be received during power off.
5.9. Filter Settings Perform Filter (HPF/LPF) settings of Input / Output channels. 9000Series Amplifier responds with the same data as that received. Note: Command cannot be received during power off.
5.10. Input Sensitivity Setting Performs input sensitivity setting of Input channel. 9000Series Amplifier responds with the same data as that received. Input sensitivity setting is enabled only for the channel on which the D-001T or AN-001T is used. Note: Command cannot be received during power off.
6. Channel Name Request Reads input and output channels’ names. The 9000 Series Amplifier responds with the channel name to this command. F0H, 03H, 40H, , 00H: Input channel 01H: Output channel 00H - 07H (Input channel 1 - 8) 00H - 07H (Output channel 1 - 8) Example: Acquiring the Input Channel 1’s name. F0H, 03H, 40H, 00H, 00H Response data are provided below.
7. Speaker Preset Setting Recalls speaker EQ preset values for specific TOA model speakers. 9000Series Amplifier responds with the same data as that received. Note: Command cannot be received during power off.
8.
9.
Command Controller A-9000 Response Input sensitivity setting Input ch1 Insense -24dB ACH, 02H, 00H, 02H ACH, 02H, 00H, 02H Speaker preset setting Output ch2 SpPreset F-122 ADH, 02H, 01H, 01H ADH, 02H, 01H, 01H Phantom power setting Input ch3 Phantom ON 87H, 02H, 02H, 01H 87H, 02H, 02H, 01H Channel name recall Input ch1 Name “INPUT1” F0H, 03H, 40H, 00H, 00H Page 24 of 24 C0H, 09H, 00H, 00H, 49H, 4EH, 50H, 55H, 54H, 31H, 00H