Specifications
8
Caveats for Cisco IOS Release 12.0
78-6455-12
Interfaces and Bridging
Interfaces and Bridging
• CSCdk48089
Removing an ATM Deluxe card from a Cisco 7200 series router and inserting an ATM Lite card in
the same slot may cause the router to fail. There is no workaround.
• CSCdr47324
With fast switching (Optimum, Cisco Express Forwarding (CEF), or flow) enabled, a
Cisco 7200 series router may fail to route packets larger than 1496 bytes from any Fast Ethernet
(FE) interface and a Bridge Group Virtual Interface (BVI). It is also possible that the first packet
may reach its destination (because it is process-switched), but all subsequent packets will fail.
Workaround: Disable fast switching on the FE interface.
• CSCdr57358
An Inter-Switch Link (ISL) trunk does not work between a Cisco Catalyst 5500 and a
Cisco 7000 series router that is running Cisco IOS Release 12.0.7, 12.0.8, or 12.0.11 with a
PA-FE-TX port adapter that performs ISL in software microcode. This port adapter appears in the
output of the show diag privileged EXEC command as 100BASE-TX-nISL. The ISL trunk works
on the PA-FE-TX port adapter that appears in the output of the show diag privileged EXEC
command as 100BASE-TX-ISL and supports ISL in hardware.
Workaround: Create an 802.1Q trunk.
• CSCds14572
With an ATM Lite Port Adapter (PA), permanent virtual circuit (PVC) discovery fails to come up
with the right PVC parameters for variable bit rate-non real-time (VBR-NRT) service category.
This problem happens only for the ATM lite interface. There is no workaround.
• CSCds14583
A six-port CX-Ethernet Interface Processor (EIP) reloads randomly. Ports are shut down and you
must enter the no shut command to bring them back. The following traceback errors are generated
in the log:
%SYS-4-SNMP_WRITENET: SNMP WriteNet request. Writing current co nfiguration to
10.110.214.21
%STANDBY-6-STATECHANGE: Standby: 1: Ethernet3/0 state Standby - > Active
%CBUS-3-CMDTIMEOUT: Cmd timed out, CCB 0x5800FF50, slot 3, cmd code 32 -Traceback=
60289C38 6028A124 60282DB8 60283AC0 60283A98 6028DD20 603A9610 603A9 A00 603A9CBC
603AB3E8 60221844 60221830
%CBUS-4-RSETFAIL: Interface Ethernet3/0 failed to reset properl y in
cbus_mci_record_ether_address(), code 0x8010
%CBUS-4-RSETFAIL: Interface Ethernet3/0 failed to reset properl y in
cbus_mci_record_ether_address(), code 0x8010
%CBUS-3-ADDRFILTR: Interface Ethernet3/0, address filter select command failed, code
0x8010 -Traceback= 6028DC08 6028DD10 603A9630 603A9A00 603A9CBC 603AB3E8 60221844 60221
830
%CBUS-4-RSETFAIL: Interface Ethernet3/0 failed to reset properl y in
cbus_mci_record_ether_address(), code 0x8010
%STANDBY-6-STATECHANGE: Standby: 1: Ethernet3/3 state Standby - > Active
%CBUS-4-RSETFAIL: Interface Ethernet3/3 failed to reset properl y in
cbus_mci_record_ether_address(), code 0x8010 %CBUS-4-RSETFAIL: Interface Ethernet3/3
failed to reset properl y in cbus_mci_record_ether_address(), code 0x8010
%CBUS-4-RSETFAIL: Interface Ethernet3/3 failed to reset properl y in
cbus_mci_record_ether_address(), code 0x8010
%CBUS-4-RSETFAIL: Interface Ethernet3/3 failed to reset properl y in