Specifications

Futurebus+ Bus Support
15.11 Futurebus+ on DEC 4000
Figure 15–9 DEC 4000 ADP list
DEC 4000 ADP List
IOC$GL_ADPLIST
adp$ps_child_adp
adp$ps_peer_adp
System ADP
Lbus ADP
TR = 1
type = AT$_KA0202
header
14
entries
Lbus Fbus
Bus Array Bus Array
ZK6734AGE
Local I/O devices
TR = 2
type = AT$_KA0202_LBUS
Fbus ADP
TR = 3
type = AT$_FBUS
5 SCSI/DSSI ports
2 NI ports
Serial line
12C
header
9
entries
Futurebus+ options
Entry 0 Fbus Bridge
Entry 1 empty
Entries 2 13 user Futurebus+
options (corresponding to
backplane slots 1 6)
15.12 Futurebus+ on DEC 10000/7000
This section describes some of the details of DEC 10000/7000 Futurebus+
implementation.
15.12.1 The DEC 10000/7000 Futurebus+ Bridge
The DEC 10000/7000 platform contains an IOP module which interfaces to the
DEC 10000/7000 I/O subsystem. The IOP supports up to 4 bridges to remote
I/O buses. Currently the supported I/O buses on DEC 10000/7000 are XMI and
Futurebus+. The Futurebus+ bridge on DEC 10000/7000 is implemented in a
distinct Futurebus+ module called the Flag. The DEC 10000/7000 Futurebus+
backplanes are 10 slots. The Flag must be installed in slot 5. Slots 0-4 and 6-9
are available for user Futurebus+ options.
15–14