Owner`s manual
DRAFT
Upgrading a VAX 6000 to a Model 600 may require changing some other
modules. If you have BI or CI I/O options, for example, you may need to
change adapters for those modules. Table 2–1 tells what modules can and
cannot be used with the H9657-CX upgrade and with all other upgrades.
Table 2–1: Upgrading Modules for the Model 600
Module
Upgrade with
H9657-CX Kit
Other
Upgrades
MS62A memory No No
MS65A memory Yes Yes
DWMBA adapter Yes No
DWMBB adapter Yes Yes
CIBCA-A adapter No No
CIBCA-B adapter Yes Yes
KA64A vector module No No
CAUTION: You must wear an antistatic wrist strap attached to the cabinet
when you handle any modules.
When you take out a module from the XMI card cage, follow these rules:
1. Lift the card cage handle for the slot being dealt with and make sure it
is firmly in place. (You may need to hold the handle up until you have
started sliding the module out.)
2. Remove the old module, holding it by the corners as shown in
Figure 2–2.
3. Make sure that no part of the module touches another module or a
cable.
4. Place the module in an electrostatic discharge (ESD) box or on an ESD
mat. If a mat, make sure the mat is on a stable, uncluttered surface.
Side 1 of the module (with the heat sinks) should face up.
5. Return processor modules, as described in Section 2.4.
Preparing for the Installation (All Upgrades) 2–7