Owner`s manual

DRAFT
To verify the upgraded system:
1
Power up the system. The power-up tests run and test all individual
modules. CPU/memory interaction, multiprocessor tests, additional
memory tests, and DWMBB tests are also part of the power-up testing.
See Section 6.2 and Section 6.3.
2
Set the system serial number on all processors. (Error messages
show that processor serial numbers have not been initialized.) See
Section 6.4. Set system parameters. As part of the preparation for
the upgrade, you issued a SHOW ALL console command (see Chapter
2). Using this listing, restore system-specific parameters such as boot
specifications, console baud rate, memory interleave, and so forth. See
Section 6.4.
3
Boot the VAX Diagnostic Supervisor and run the EVUCA program to
apply current ROM and PCS (Patchable Control Store) patches. See
Section 6.5.
4
Record and save the new customized parameters. First make a
hardcopy record for future maintenance with the SHOW FIELD and
SHOW ALL commands. Then, if your system has a TK tape, use the
SAVE EEPROM command. See Sections 6.6 and 6.7.
5
Verify the system under the operating system. See Section 6.8.
Verifying the System (All Upgrades) 6–3