Brochure

150 C
ARDINAL PLACE, SASKATOON, SK S7L 6H7
T
EL: (306) 955-7075 FAX: (306) 955-9919
E-MAIL: SALES@VCOM.COM WEBSITE: WWW.VCOM.COM
br_ap5857_05 (Oct 2005)
Specifications subject to change without notice. - Printed in Canada.
S
PECIFICATIONS
VC
OM
AP5857 S
TRAND
R
ADIO
S
YSTEM
The DOCSIS
TM
acronym belongs to CableLabs®
ACCESS POINT
AP5857
SUBSCRIBER UNIT
TRI5758 (WITH OPTION AP)
DOWNSTREAM
Transmit RF Output Frequency Range 5799 to 5823 MHz
Transmit EIRP +15 to +28 dBm
IF Input Frequency Range 91 to 857 MHz
IF Input Level Range 0 to +20 dBmV per channel
Downstream Modulation 64QAM, 5.06 MSym/sec or
256QAM, 5.36 MSym/sec
Downstream Flatness 1 dB p-p over 5 MHz, typical
UPSTREAM
Receive RF Input Frequency Range 5727 to 5751 MHz
Noise Figure (at RF connector) 6 dB max at max gain
Image Rejection 90 dB minimum
IF Output Frequency Range 18 to 42 MHz
Gain Range 36 ± 2 dB to 76 ± 2 dB
at mid band
IF Level 17 to 50 dBmV
Gain Flatness (frequency response) ± 0.5 dB over 3.2 MHz,
2 dBpp full band
Spectral Inversion No spectral inversion
Return Loss (IF) 13 dB: 5 to 42 MHz and
88 to 857 MHz
GENERAL
Upstream Ingress Mitigation Automatic upstream IF mute
Upstream gain control
Upstream mute control via remote access
Upstream power detector
IF Connector F female, 75 ohms
Power Requirements 35 to 90 VAC, 60 Hz
Power Consumption 27 W maximum
Management Remote and local status monitoring
and control
SNMPv1.1 remote access
RS232 command line local craft interface
Operating Temperature Range -40 to +60 °C
Antenna Integrated: 60° horz. & 30°
vert. beamwidth
Downstream Link Margin
(line of sight)
16.5 dB (64QAM, 1 mile);
3.8 dB
(256QAM, 2 miles)
EMC Compliance FCC CFR 47, Part 15, Subpart B
FCC Part 15 subpart E, section 15.401
Industry Canada RSS-210 6.2.2 (q1)
LELAN devices
Configurations Strand mount, utility pole mount, pipe
mount (options STRAND, POLE, PIPE)
Size 60.2 x 22.3 x 12.4 cm (23.7 x 8.8 x 4.9”)
Weight 7.1 kg (15.6 lbs)
DOWNSTREAM
RF Input Frequency 5799 to 5823 MHz
IF Output Frequency 540 to 564 MHz
Gain (Integrated) 36 dBi ± 2 dB
Gain Flatness (Frequency Response) ± 1.5 dB full range
± 0.5 dB any 6 MHz range
Gain Stability Over Temperature ± 2.0 dB
Noise Figure 6.0 dB typical, 7dB max
Image Rejection 90 dB minimum
Discrete Spurious (at IF port) -80 dBm between 540 and 564 MHz
-50 dBm from 5 MHz to 540 MHz and
from 564 MHz to 860 MHz
Phase Noise (IF) <-85 dBc/Hz @ 10 kHz typical
Spectral Inversion No spectral inversion
U
PSTREAM
IF Input Frequency 18 to 42 MHz
RF (upstream) Output Frequency 5727 to 5751 MHz
Gain (Integrated) 26 dBi ± 2 dB
Gain Flatness (Frequency Response) ± 1 dB full band
± 0.5 dB over any 3.2 MHz band
Gain Stability Over Temperature ± 2.0 dB
Linear Output Power +5 dBm into antenna
(16 QAM, QPSK)
Spurious (at transmit port) -40 dBm 9 kHz to 21.4 GHz
Phase Noise < -85 dBc/Hz @ 10 KHz typical
Spectral Inversion No spectral inversion
Return Loss (IF) 10 dB in transmit
and receive bands
IF Level for RF Activation + 5 dBmV
RF Activation/Mute Response Time <2 microseconds
G
ENERAL
Integrated Flat Panel Antenna
Gain 23 dBi
Beamwidth 9.0 degrees
Polarity Vertical or horizontal
Cross Polarization Isolation 20 dB
Front/Back Ratio 30 dB
IF Connector F female, 75 ohms
DC Supply 18 to 24 VDC, 12W max.
Operating Temperature -40°C to +60°C
Size 30.5 x 30.5 x 7.5 cm (12 x 12 x 3")
Mounting Pole mount
1" to 2.5" dia. pole or wall
mount with 90 deg pol,
az and el adjustment
Weight 2.7 kg max.
Part Number TRI5758, option AP