User Manual

VCom Inc.
AP5857 Manual; ml_ap5857_08 (Oct 2005)
Approved: R.B.
20
Upstream Output Threshold Alarm
When active and the alarm is enabled, it indicates that the upstream output level is higher than the upstream
output alarm threshold value. The upstream signal is muted under this condition. It will indicate “OK” or
“Threshold Exceeded”.
Downstream CATV Frequency
Indicates the frequency of the signal from the CATV strand to which the the radio is currently tuned.
Downstream RF Frequency
Indicates the frequency of the RF transmit signal to which the radio is currently set.
Downstream Transmit EIRP Setting
Indicates the current downstream transmit power setting, expressed as Effective Isotropic Radiated Power
(EIRP).
Downstream Output
Indicates current state of the downstream output. There are three valid output states: Muted (Manual)
indicates that user has forced the output to be disabled, Muted (Alarm) indicates that the output has been
muted by an alarm condition, Unmuted indicates that the output is enabled.
Downstream Modulation
Indicates the selected downstream modulation. It will indicate 64QAM or 256QAM.
Downstream Interleaver
Indicates the selected downstream interleaver setting. Valid settings are 128,1; 64,2; 32,4; 16,8; and 8,16.
See the downstream menu section for details on interleaver settings.
Downstream Demodulator Status
Indicates the lock status of the downstream demodulator. It will display Locked or Not Locked. If the
demodulator is not locked, this may indicate that there is no valid signal or the signal quality is too low for
proper operation.
Downstream Demodulator SNR
Indicates the estimated downstream Signal to Noise Ratio as seen by the demodulator. The best signals will
result in SNR values of 35 dB or more, however good operation will be maintained to SNR values of 30 dB or
less. Lower SNR values indicate poor signal conditions, which may include interference or low signal level.
The indicated SNR is an instantaneous reading, so the value of the SNR will vary from reading to reading.
Upstream Gain
Indicates the current upstream gain setting.
Upstream Level
Indicates the latest reading of the upstream signal level at the IF port. Pushing E
NTER will update the screen
with a new measurement.