Reset Unit
The reset menu option allows the unit to be reset.
To reset the unit, type “5”. The local interface prompt will change to:
Reset Unit [Y/N](N)>_
Enter Yes to reset the unit or enter No or press ENTER to abort.
Load Factory Defaults
The Load Factory Defaults allows the user to put all the radio settings into a known state. The settings are:
Vendor Information
Vendor Name VCom Inc.
Serial Number [system serial number]
Model AP5857
Hardware Rev PC3B0105 [or as appropriate]
Downstream Settings
Output Frequency 5808 MHz
Output EIRP 28 dBm
Downstream Modulation 64QAM
Downstream Interleaver 16,8
Output Mute 0 [unmuted]
Upstream Settings
Gain 50 dB
Output Mute 0 [unmuted]
Output Auto Mute Threshold 30
Output Alarm Threshold 50
Output Alarm Threshold Enable 0 [disabled]
General Settings
Password [no change]
User Message [no change]
Antenna Gain 12
Ethernet Settings
SNMP Enable 1 [enabled]