User's Manual Part 1

7: Configuring the CCU
APCD-LM043-8.0 (DRAFT C) 125
Sets the SNMP contact as WaveRider,
Sets the SNMP location as Calgary_South,
Adds SNMP read community
WaveRider_Calgary,
Adds SNMP write community
WaveRider_Calgary,
Adds SNMP trap server
WaveRider_Calgary, IP address 10.0.1.68,
Saves the new settings, and
Displays the SNMP settings.
Example:
60:03:3a>
60:03:3a> snmp contact WaveRider
60:03:3a> snmp location Calgary_South
60:03:3a> snmp community add WaveRider_Calgary read
60:03:3a> snmp community add WaveRider_Calgary write
60:03:3a> snmp trap add 10.0.1.68 WaveRider_Calgary
60:03:3a>
60:03:3a> save
Basic Config saved
Port Filter Config saved
sntp cfg file saved
Route Config saved
Authorization Database saved
DHCP Server Config saved
60:03:3a>
60:03:3a> snmp
Contact: WaveRider
Location: Calgary_South
Name: LMS3000
SNMP Read Communities:
WaveRider_Calgary
SNMP Write Communities:
WaveRider_Calgary
SNMP Traps:
10.0.1.68 WaveRider_Calgary
60:03:3a>
7.9 Adding EUMs to the Authorization Table
EUMs can be authorized either statically in the authorization table or through a RADIUS
server.
To Add an EUM to the CCU Authorization Table
1. Type auth add <eum id> <gos> and press Enter.
NOTE: <gos> is the grade of service that you want to assign to the EUM,
one of: be (best effort), bronze, silver, gold, or denied.
2. Type
save or commit and press Enter.
The “auth” command takes effect immediately.