User's Manual Part 1

140 APCD-LM043-8.0 (DRAFT C)
8: Configuring the EUM
8.5 Configuring SNMP
The procedure for configuring SNMP on an EUM is identical to the procedure for a CCU. To
fully configure SNMP
Set the SNMP contact (name of the WISP, for example).
Set the SNMP system location (physical location of the EUM, for example).
Add an SNMP read community.
Add an SNMP write community.
Add an SNMP trap server.
To Set the SNMP Contact
1. Type snmp contact <contact> and press Enter.
<contact> is a name and phone number, a URL, or an email address, from 1-
80 characters in length.
2. Type
save or commit and press Enter.
To Set the SNMP System Location
1. Type snmp location <location> and press Enter.
<location> is the location of the EUM, from 1-80 characters in length.
2. Type
save or commit and press Enter.
To Add an SNMP Read Community
1. Type snmp community add <community> read and press Enter.
<community> is the name of the read community string. The default read
community string is “public”. The read community string can be from 1-31
characters in length, but spaces are not allowed.
2. Type
save or commit and press Enter.
To Add an SNMP Write Community
1. Type snmp community add <community> write and press Enter.
<community> is the name of the write community string. The default write
community string is “private”. The write community string can be from 1-31
characters in length, but spaces are not allowed.
2. Type
save or commit and press Enter.
To Add an SNMP Trap Server
1. Type snmp trap add <aaa.bbb.ccc.ddd> <community> and press Enter.
<aaa.bbb.ccc.ddd> is the IP address of the trap server
<community> is the name of the community on the trap server, from 1-63
characters in length.
2. Type
save or commit and press Enter.