4: Installation
APCD-LM048-1.1 29
Figure 6 EUM3006 Mounting - Horizontal Orientation
4.3.3 Running Cables
Secure the Ethernet cable and grounding conductor along the pole mounting hardware, the
roof and/or any exterior walls, using standard cable ties or anchors, so that there is little or no
strain on the wires, but they will not flap in the wind. Add lengths of straight-through Ethernet
cables if the provided cable is not long enough. See Appendix B on page 39 for more
information on Ethernet cables.
Attach the grounding conductor to the building’s Power Service Grounding Electrode System
using a ground clamp. See Important Safeguards on page xiv for discussion on good
grounding practices.
If a PoE lightning arrestor is used, it must also be grounded through the building’s Power
Service Grounding Electrode System. The Ethernet cable from the EUM3006 is attached to
the external port of the lightning arrestor and a straight-through Ethernet cable is attached to
the other port.
Ethernet Port
Gear Clamps
Drip Loops
TOP Marking
Ground Connection
and GND Marking