750W Power Inverter OWNER’S MANUAL Model number -457750 Keep away from WATER、FIRE、SMOKE! TO REDUCE THE RISK OF INJURY, USER MUST READ AND UNDERSTAND THIS INSTRUCTIONAL MANUAL. THIS MANUAL CONTAINS IMPORTANT INFORMATION REGARDING THE OPERATION AND WARRANTY OF THIS PRODUCT. PLEASE RETAIN FOR FUTURE REFERENCE.
CONTENTS 1. Introduction..............................................................................................2 2. Important Safety Information................................................................... 2 3. Features.................................................................................................. 4 4. Connecting the inverter........................................................................... 6 5. Operating the inverter..................................................
1. Introduction Thank you for purchasing the NPower 750W Power Inverter, a high performance solution to use household power while on the road. Connected to the 12V volt output in your vehicle, the inverter efficiently and reliably supplies 110V/60Hz AC power for a wide variety of loads, such as all kinds of jacklights, TV sets, audio/video systems and electromotion tools with power consumption under 750 watts. It has been tested and found to be in line with the requirement of ETL certification.
Warning! The case to the unit may become very warm under high power operation reaching 140°F(60°C). Be sure that there is at least 2 in (5cm) of unobstructed air space around the entire surface of the inverter at all times. During use, do not place materials that could be damaged by heat near the unit. Warning! Do not operate the unit near flammable fumes or gases such as the cabin of a gasoline power boat, or near propane tanks.
Certain battery chargers for battery packs used in hand power tools. These chargers will have a warning label indicating that dangerous voltages are present at the battery terminals. Caution! Connect the unit to batteries with a normal output of 12V DC only. As 6V batteries voltage is too low, and a 24V battery voltage is too high which will damage the unit. Additional Safety Guidelines! Do not insert any foreign objects into the unit outlets, vents or fan openings.
Fig. 2 4 Green LED Indicator— When there is DC power input, the green LED indicator lights. 5 Red LED Indicator— When the inverter has shut down because of low or high input voltage, the red LED indicator lights. 6 Button Power Switch— Connect the inverter to the DC power and press down the button power switch, the AC power is available. Fig.3: AC Outlet Panel 5.
AC Outlets— They allow you to plug in 110V AC products with a total continuous of 750W or less. 8 USB Port— Offer 5V power to USB equipment. 9 Ventilation Openings—The ventilation openings should not be covered at any time while the inverter is operating. Fig.4: Wiring 10 DC Cable with Clips—Connect the red clip to the positive terminal of the battery, and the black to the negative. 4.
Do not operate the unit in the same compartment as Safe batteries or in any compartment capable of storing flammable liquids like gasoline. Do not operate the unit in an area that is prone to dirt, dust Clean or debris. Especially important if used in a work environment. Your 750W Power Inverter supplies 750 watts of continuous power with 1500 watts of surge power. When you turn on an appliance or a tool that operates using a motor or tubes, it requires an initial surge of power to start up.
cables to overheat, resulting in equipment damage or fire. 5) 6) Turn on the inverter. When the power inverter is not in use, disconnect the DC cable clips from the battery to prevent slight discharge of battery. 5. Operating the inverter 1) When properly connected to a 12V outlet or battery, turning on the inverter, will illuminate the green LED light, and deliver AC power to the outlet(s). 2) Plug the AC product(s) you wish to operate into the AC outlet(s) and switch them on, one at a time.
extended periods of time, you should consider connecting the unit to a separate deep discharge battery. Should a defective battery charging system cause the battery voltage to rise to the range of 15.0V~16.0VDC, the inverter automatically shuts down; and the red LED lights. Caution! If there are one more AC products connecting to the inverter, turn on the larger power product first. If an AC product rated higher than 750W (or which draws excessive surge power) is connected, the inverter will shut down.
Buzzing and in audio systems and radios Some stereo systems and AM-FM radios have inadequate internal power supply filtering and “buzz” slightly when powered by the inverter. Generally, the only solution is an audio product with a higher quality filter. Television interference The inverter is shielded to minimize its interference with TV signals. However, with weak TV signals interference may be visible in the form of lines scrolling across the screen.
The voltage input is too low charge the battery (alarm is sounding). Unplug inverter from DC socket and allow to be TInverter is overheated due to poor ventilation and has shut down. cooled for 15 minutes. Remove objects covering unit. Move the inverter to a cooler place. Reduce load if continuous operation is required. Restart. Inverter runs small loads but not large Low voltage battery Charge the battery ones.
Standard “average-reading” Inverter’s “modified sine Measured AC voltmeter used to wave” output requires “ inverter measure output voltage, true RMS” voltmeter for output is too low resulting in an apparent accurate measurements. reading 5 to 15V too low. Battery voltage is too low. Recharge battery. AC product power Use a larger battery to consumption is higher make up for increased than rated. power requirement. Battery is old or properly Replace battery. defective.
AC output waveform Modified sine wave USB Power Output AC output frequency(nominal) 5 V DC DC Power Specifications DC input voltage range 13±0.2V DC Battery drain with no AC load 0. 5A (at a 12V input) Low battery alarm trigger point 11.0±0.3V DC Low battery shutdown point 10.5±0.3V DC (nominal) Low battery shutdown resume 12.0±0.3V DC point (nominal) High battery shutdown point 15.5±0.
8. Warranty One Year Limited Warranty Program NPower warrants this product for one year limited against any defects in materials or workmanship. The defective products will be replaced and repaired at no charge in either of one year. This warranty lasts for 12 months from the date of purchase at the point of sale to you. This warranty does not apply where the product has been misused, improperly installed, physically damaged or altered, either internally or externally, or damaged from improper use.