Specifications

Section 1
General Information
A-6 Appendix A MN722
Table A-3 Power Output Parameter Block Values Level 2 Continued
Level 2 Blocks - Continued
Block Title Parameter P# Adjustable Range Factory User
Setting
BRAKE RESISTOR OHMS 2601 0-250.0 Ohms Factory Set
ADJUST
RESISTOR WATTS 2602 0-360.00 Watts Factory Set
DC BRAKE CURRENT 2603 0-100% 0
PROCESS
CONTROL
PROCESS FEEDBACK 2701 0 POTENTIOMETER
1 +/-10VOLTS
2 +/-5 VOLTS
3 4 To 20mA
4 5V EXB
5 10V EXB
6 4-20mA EXB
7 3-15 PSI EXB
8 TACHOMETER EXB
9 NONE
NONE
PROCESS INVERSE 2702 0OFF, 1 ON OFF
SETPOINT SOURCE 2703 0 POTENTIOMETER
1 +/-10VOLTS
2 +/-5 VOLTS
3 4 To 20mA
4 5V EXB
5 10V EXB
6 4-20mA EXB
7 3-15 PSI EXB
8 TACHOMETER EXB
9 NONE
10 SETPOINT CMD
SETPOINT
CMD
SETPOINT COMMAND 2704 100.0% to +100.0% 0.0 %
SET PT ADJ LIMIT 2705 0-100.0% 10.0 %
PROCESS ERR TOL 2706 1-100% 10 %
PROCESS PROP GAIN 2707 0-2000 0
PROCESS INT GAIN 2708 0-9.99 HZ 0.00 HZ
PROCESS DIFF GAIN 2709 0-1000 0
FOLLOW I:O RATIO 2710 (1-65535) : (1-20) 1:1
FOLLOW I:O OUT 2711 1-65535 : 1-65535 1:1
MASTER ENCODER 2712 50-65535 1024 PPR