3.1 Time Synchronization
3.1.1 General Information
Time stamps
and events
Time stamps are useful when analyzing incoming or outgoing data or event
sequences on a specific bus.
Figure 39: Time stamps of two CAN channels in CANalyzer.
Generating
time stamps
Each event which is sent or received by a Vector network interface has an accurate
time stamp. Time stamps are generated for each channel in the Vector network
interface. The base for these time stamps is a common hardware clock in the device.
Figure 40: Common time stamp clock for each channel.
If the measurement setup requires more than one Vector network interface, a
synchronization of all connected interfaces and their hardware clocks is needed.
Due to manufacturing and temperature tolerances, the hardware clocks may vary in