Parameterizing steps Vector Control Chassis Type Frequency Converter
476 869 4070 76 J AB-74 Siemens AG
9-44 Operating Instructions SIMOVERT MASTERDRIVES
9.4 Notes on parameterization
The parameter list covers the setting parameters and visualization
parameters of all available motor types (induction motors and
synchronous motors), as well as all possible open-loop and closed-loop
control modes (e.g. V/f characteristic, speed control).
The constellation under which this parameter is influenced or whether it
is displayed at all is indicated under "Preconditions" in the parameter
description.
Unless otherwise specified, all percentage values refer to the reference
quantities in P350 to P354.
If reference quantities are changed, this will also change the
significance of the parameters with percentage normalization (e.g.
P352 = Maximum frequency).
Function diagrams and start-up instructions for separately excited
synchronous motors (with damping cage and excitation via sliprings)
are available as separate instructions.
The following parameters are only effective for these synchronous
motors:
P75 to P88; P155 to r168, P187, P258, P274, P297, P298, P301, r302,
P306 to P312.
The following parameters are calculated or set to fixed values during
automatic parameterization (P115 = 1):
P116 P236 P295 P337
P117 P240 P303 P339
P120 P258 P306 P344
P121 P259 P313 P347
P122 P273 P315 P348
P127 P274 P316 P388
P128 P278 P319 P392
P161 P279 P322 P396
P215 P283 P325 P471
P216 P284 P326 P525
P217 P287 P334 P536
P223 P291 P335 P602
P235 P293 P336 P603
P350 to P354 are only set to the rated motor quantities in the
converter status "Drive setting" (P060 = 5) or "Quick
parameterization (P060 = 3).
Automatic parameterization is also carried out by the standstill
measurement P115 = 2, 3.