VEC024 400 WATT POWER INVERTER NEW SOFT START TECHNOLOGY 800 WATT PEAK OWNER’S MANUAL & WARRANTY INFORMATION THIS MANUAL CONTAINS IMPORTANT INFORMATION REGARDING SAFETY, OPERATION, MAINTENANCE AND STORAGE OF THIS PRODUCT. BEFORE USE, READ AND UNDERSTAND ALL CAUTIONS, WARNINGS, INSTRUCTIONS AND PRODUCT LABELS, PLUS YOUR VEHICLE’S BATTERY MANUFACTURER GUIDELINES. FAILURE TO DO SO COULD RESULT IN INJURY AND/OR PROPERTY DAMAGE. 4140 SW 28TH WAY, FT.
IMPORTANT SAFETY INSTRUCTIONS To ensure reliable service, your power inverter must be installed and used properly. Please read the installation and operating instructions thoroughly prior to installation and use. Pay particular attention to the WARNING and CAUTION statements in this manual. The CAUTION statements advise against certain conditions and practices that may result in damage to your inverter. The WARNING statements identify conditions or practices that may result in personal injury.
CONTENTS 1. INTRODUCTION ..........................................................4 2. CONTROLS, INDICATORS AND CONNECTORS ..................4,5 3. HOW YOUR INVERTER WORKS ..............................................5 3.1 Principal of Operation ......................................................5 3.2 The MaxxSST 400 Output Waveform ....................................6 4. INSTALLATION..............................................................6 4.1 Power Source Requirements ........................
1. INTRODUCTION Your new Vector MAXX 400 SST inverter is one in a series of the mostadvanced DC to AC inverters available today. With proper careandappropriate usage, it will give you years of dependable service in your car, truck, RV or boat.
FIGURE 1 4 1. RED SHUT DOWN LED 2. GREEN OPERATING LED 3. 2 110 VAC RECEPTACLES 4. ON/OFF SWITCH 3 2 FIGURE 2 1 2 1. HIGH SPEED COOLING FAN 2. (+) DC POWER CONNECTION 3. (–) DC POWER CONNECTION 1 3 3. HOW YOUR VECTOR INVERTER WORKS The inverter converts low voltage DC (direct current) from a battery or other power source to standard 110 volt AC (alternating current) household power. 3.1 PRINCIPLE OF OPERATION The inverter converts power in two stages.
3.2 THE MAXX SST 400 WATT OUTPUT WAVEFORM The AC output waveform of the MAXX 400 SST is known as “modified sine wave”. It is a waveform that has characteristics similar to the sine wave shape of utility power. This type of waveform is suitable for most AC loads, including linear and switching power supplies used in electronic equipment, transformers, and motors.
Example: If a load is rated at 400 watts AC, the power source must be able to deliver: 400 divided by 10 = 40 amperes CAUTION: The MAXX 400 SST must be connected only to batteries with a nominal output voltage of 12 volts. The unit will not operate from a 6 volt battery and will sustain permanent damage if connected to a 24 volt battery. 4.
3. 4. Connect the red cable to the red post marked “(+)” on the back of the inverter. Connect the battery clip to the positive terminal of the battery. Check to be sure that all connections between battery clips and terminals are secure. Direct Hardwiring to Power Source: Use #10 AWG wire if the inverter to power source connection is 12 feet or less. For longer cable lengths use #8 AWG wire.
4.3 CONNECTION TO LOAD The MAXX 400 SST is equipped with dual standard North American AC power receptacles. Plug the cord from the equipment you wish to operate into the AC receptacle(s). The green LED indicator lights to indicate that the inverter is functioning. Make sure the combined load requirement of your equipment does not exceed 400 SST watts. The MAXX 400 SST is engineered to be connected directly to standard electrical and electronic equipment in the manner described above.
air circulation around the unit. Do not place items on or over the inverter during operation. A fan is helpful if the inverter is operating at maximum power outputs for extended periods of time. The unit will shut down if the internal temperature exceeds operating temperatures. The unit will restart after it cools. SAFE - Do not use the inverter near flammable materials or in any locations that may accumulate flammable fumes or gases. 5. OPERATING TIPS 5.
every 2 to 3 hours to recharge the battery system. This will guard against any unexpected shut-down of the equipment and will ensure that there is always sufficient battery capacity to start the vehicle’s engine. The inverter will sound it’s alarm when DC voltage drops to 10.6 volt. The inverter may be used whether or not the vehicle’s engine is running. However, the inverter may not operate while the engine is starting since the battery voltage can drop substantially during cranking.
recharged. The user should stop operation of the electronic device at this time since the inverter will shut down automatically shortly thereafter, when the battery voltage drops to 10 volts. Start your engine to recharge the battery. If the low voltage alarm sounds when the battery is fully charged, follow the steps for solving lack of output power in the Troubleshooting Guide.
8. TROUBLESHOOTING GUIDE: TABLE 1 - INVERTER POWER SWITCH TURNED ON TROUBLE/ INDICATION No AC output – red LED lit POSSIBLE CAUSE DC input below 10 volts SUGGESTED REMEDY Recharge or replace battery No AC output – red LED lit Excessive appliance load-thermal shutdown then turn ON Reduce load-wait for inverter to cool.
9. FUSE REPLACEMENT If external fuses blow, (or breakers trip), then there is a short or overload in the DC wiring. Find and fix the problem before replacing the fuses (or resetting the breaker). After fuse replacement, reconnect the inverter. This power inverter is equipped with multiple internal fuses. Normally, these fuses will not blow unless there is a serious problem inside the unit. Internal fuses are replaceable, however, only electronically knowledgeable people should attempt fuse replacement.
purchaser only, to be free of defects in materials and workmanship for two years from the date of purchase without additional charge. The warranty does not extend to subsequent purchasers or users. Vector Manufacturing, Ltd. will not be responsible for any amount of damage in excess of the retail purchase price of the product under any circumstances. Incidental and consequential damages are specifically excluded from coverage under this warranty. This product is not intended for commercial use.
© 2004 VECTOR MANUFACTURING, Ltd. FT.