Installation manual

Série 32 Mlift Vector - Prog.Vectorielle Installation manual Chapter VII - page 79
INPUTS DEFINITIONS
Segment
4
:
MAN
(Emergency Operation).
This shows us the state of the contact which switches to emergency operation (MAN and
0V).
Segment 4 is off when the contact is closed, i.e.; normal.
Segment 4 is on when the contact is open, i.e., when in emergency operation.
Segment
3
:
INS
(Inspection).
This shows us the state of the contact which switches to inspection (INS and 0V).
Segment 3 is off when the contact is closed, i.e., normal.
Segment 3 is on when the contact is open, i.e., when being inspected.
Segment
2
:
GM
(Up).
This shows us the state of the request movement contact in Up (GM and 0V).
Segment 2 is on when the contact is closed for an upward travel request. (GM and 0V).
Segment 2 is off in the reverse case.
Segment
1
:
GD
(Down).
This shows us the state of the movement request contact in Down (GD and 0V).
Segment 1 is on when the contact is closed for a downward travel request.
Segment 1 is off in the reverse case.
Segment
0
:
MASS
(MASS Relay).
This shows us the state of the MASS relay.
Segment 0 is on if there is a mass fault.
Segment 0 is off in the reverse case.
Ram Address
0D:
best displayed in segment mode.
Segment
7
: Not used
Segment
6
: Not used
Segment
5
:
PH
(Phase Failure Input).
This shows us the state of the Phase Failure Input (PH and 0V).
Segment 5 is on when there is no phase.
Segment 5 is off in the reverse case.
Segment
4
:
THV
(Fan thermistor) TRACTION.
This shows us the state of the Fan thermistor (THV and OV).
Segment 4 is on when the contact is closed in case of a fault.
Segment 4 is off in the reverse case.