Installation manual

Série 32 Mlift Vector - Prog.Vectorielle Installation manual Chapter VII - page 95
{
}
CONTROLLER PARAMETERS TABLE (1/2)
Add Seg. 7 Seg. 6 Seg. 5 Seg. 4 Seg. 3 Seg. 2 Seg. 1 Seg. 0
00
CLF - CODE FOR LAST FAULT
01
CFBL - CODE OF FAULT BEFORE LAST
02
REGUL DPLX ISO RMLIFT NIVSIN DSERVS OUAVAR FACTORY
03
NBDOR - NUMBER OF DOOR OPERATORS
04
TOPLEV - TOP LEVEL
05
BOTLEV -BOTTOM LEVEL
06
LOBBY - MAIN FLOOR
07
SAPB CONFAL NODOOR MAN INS SPL INS CALSLZ EDOP DRODD
08
2S/RECA
V1
LCF DIF ALLAN CALCAN GFD RLVDC RLVDO
09
GONGLEV
DORFALT FSINS NOFSDI FIRESV OSDC FIRETYP
0A
TIG - INTEGRATOR’S DURATION (2 TO 45 SECONDS [IN SECONDS])
0B
TPV - SLOW SPEED DURATION (3 TO 255 SECONDS [IN SECONDS])
0C
TPLU - AUTOMATIC LIGHT DURATION (2 TO 255 SECONDS [IN SECONDS])
0D
TINS - INSPECTION DURATION (1 TO 255 SECONDS [IN SECONDS])
0E
TCAPGV - TAPE HEAD FAST SPEED TIME (2 TO 25,5 SECONDS [IN
1
/
10
SECONDS])
0F
TCAPPV - TAPE HEAD SLOW SPEED TIME (3 TO 25,5 SECONDS [IN
1
/
10
SECONDS])
10
MSQCAB - MASK FOR CAR CALLS FROM 7 TO 0
11
MSQCAB - MASK FOR CAR CALLS FROM 15 TO 8
12
13
MSQMO - MASK FOR ASCENDING FLOOR CALLS FOR LEVEL FROM 7 TO 1
14
MSQMO - MASK FOR ASCENDING FLOOR CALLS FOR LEVEL FROM 15 TO 8
15
16
MSQDE - MASK FOR DECENDING FLOOR CALLS FOR LEVEL FROM 7 TO 0
17
MSQDE - MASK FOR DECENDING FLOOR CALLS FOR LEVEL FROM 15 TO 8
18
19
TPISO - RELEVELLING TIMING (2 TO 10 SECONDS [IN SECONDS])
(with slotted tape)
PVCRH
(with vanes)
PVCRB
(with vanes)
1A
Not used CROSSED VANES FOR SHORT INTERFLOOR 7-8 / 0-1 Only
1B
with slotted tape CROSSED VANES FOR SHORT INTERFLOOR 15-16 / 8-9 with vanes
1C
1D
NUSPLX - NUMBER OF SIMPLEX (00 or 1)
1E
TFR10 - FILTERING OF « 10 » (0 TO 0,5 SECONDS [IN
1
/
100
SECONDS])
1F
TPRAU - HOMING TIME (1 TO 255 SECONDS [IN SECONDS])
20
RAUFAC1 RAUFAC2 TRAPM NIVRAU - HOMING FLOOR
21
TGONG - GONG DURATION (0,1 TO 10 SECONDS [IN
1
/
10
SECONDES])
22
COMDEM - NUMBER OF CAR TRIPS : 2 RIGHT HAND DIGITS
23
COMDEM - NUMBER OF CAR TRIPS : 2 MIDDLE HAND DIGITS
24
COMDEM - NUMBER OF CAR TRIPS : 2 LEFT HAND DIGITS
25
NUMAR0 - ID NUMBER OF THE CONTROLLER (UNITS/DIZAINES)
26
NUMAR1 - MONTH OF PRODUCTION OF THE CONTROLLER (IN HEXADECIMAL)
27
NUMAR2 - YEAR OF PRODUCTION OF THE CONTROLLER
28
REPT00 - POSITION INDICATOR AT LEVEL 00
29 to 36
REPTxx - POSITION INDICATOR AT LEVEL xx
37
REPT15 - POSITION INDICATOR AT LEVEL 15
ADAPTATION FOR A SPECIFIC NON-CLASSED HYDRAULIC POWER UNIT ( CYHYD )
38
V4 V3 V2 V1 LINE DELTA STAR
39
V4 V3 V2 V1 LINE DELTA STAR
3A
V4 V3 V2 V1 LINE DELTA STAR
3B
V4 V3 V2 V1 LINE DELTA STAR
3C
V4 V3 V2 V1 LINE DELTA STAR
3D
V4 V3 V2 V1 LINE DELTA STAR
3E
V4 V3 V2 V1 LINE DELTA STAR
3F
V4 V3 V2 V1 LINE DELTA STAR
40
RGPT VERSTF1 P1SFCOU P1SFCFE PMAFCP1 MSTPMP1 AMPSEC1 MSTPRP1
41
TP01 - FRONT DOOR TIME (2 TO 255 SECONDS [IN SECONDS])
42
TREP1 - FRONT DOOR RE-OPEN TIME (1 TO 255 SECONDS [IN SECONDS])
43
FRONT REAR NIVMHS - OUT OF SERVICE FLOOR
44
TIRP1 - FRONT DOOR RELAY INVERSION TIME (0 TO 2,55 S. [IN
1
/
100
SEC])
45
TFR8 - FILTERING OF « 8 » (0 TO 2,55 S. [IN
1
/
100
SEC])
46
TVP1/2 - FRONT AND REAR DOOR LOOK TIME (1 TO 255 S. [IN SEC])
47
TIGPO1 - FRONT DOOR INTEGRATOR TIME (1 TO 255 SECONDS [IN SECONDS])