MSDS

FLAMMABLE LIMITS/PERCENT VOLUME IN AIR: LOWER: 1 UPPER: 7
EXTINGUISHING MEDIA:
USE WATER FOG, FOAM, DRY CHEMICAL OR CO2. DO NOT USE A DIRECT STREAM OF WATER.
PRODUCT WILL FLOAT AND CAN BE REIGNITED ON SURFACE OF WATER.
SPECIAL FIRE FIGHTING PROCEDURES AND PRECAUTIONS:
CAUTION. COMBUSTIBLE. DO NOT ENTER CONFINED FIRE SPACE WITHOUT FULL BUNKER GEAR
(HELMET WITH FACE SHIELD, BUNKER COATS, GLOVES AND RUBBER BOOTS), INCLUDING A
POSITIVE PRESSURE NIOSH APPROVED SELF-CONTAINED BREATHING APPARATUS. COOL FIRE
EXPOSED CONTAINERS WITH WATER.
UNUSUAL FIRE AND EXPLOSION HAZARDS:
CONTAINERS EXPOSED TO INTENSE HEAT FROM FIRES SHOULD BE COOLED WITH WATER TO
PREVENT VAPOR PRESSURE BUILDUP WHICH COULD RESULT IN CONTAINER RUPTURE. CONTAINER
AREAS EXPOSED TO DIRECT FLAME CONTACT SHOULD BE COOLED WITH LARGE QUANTITIES OF
WATER AS NEEDED TO PREVENT WEAKENING OF CONTAINER STRUCTURE.
SECTION IX REACTIVITY
STABLITY: STABLE HAZARDOUS POLYMERIZATION: WILL NOT OCCUR
CONDITIONS AND MATERIALS TO AVOID:
AVOID HEAT, FLAME AND CONTACT WITH STRONG OXIDIZING AGENTS.
HAZARDOUS DECOMPOSITION PRODUCTS:
CARBON MONOXIDE AND UNIDENTIFIED ORGANIC COMPOUNDS MAY BE FORMED DURING COMBUSTION.
SECTION X EMPLOYEE PROTECTION
RESPIRATORY PROTECTION:
AVOID PROLONGED OR REPEATED BREATHING OF VAPORS. USE A NIOSH-APPROVED RESPIRATOR
AS REQUIRED TO PREVENT OVEREXPOSURE. IN ACCORD WITH 29 CFR 1910.134, USE EITHER AN
ATMOSPHERE-SUPPLYING RESPIRATOR OR AN AIR-PURIFYING RESPIRATOR FOR ORGANIC VAPORS.
PROTECTIVE CLOTHING
AVOID CONTACT WITH EYES. WEAR SAFETY GLASSES OR GOGGLES AS APPROPRIATE. AVOID
PROLONGED OR REPEATED CONTACT WITH SKIN. WEAR CHEMICAL-RESISTANT GLOVES AND OTHER
CLOTHING AS REQUIRED TO MINIMIZE CONTACT.
ADDITIONAL PROTECTIVE MEASURES:
USE VENTILATION AS REQUIRED TO CONTROL VAPOR CONCENTRATIONS. AIR-DRY CONTAMINATED
CLOTHING IN A WELL VENTILATED AREA, THEN LAUNDER BEFORE REUSING.
SECTION XI ENVIRONMENTAL PROTECTION
SPILL OR LEAK PROCEDURES:
CAUTION. COMBUSTIBLE. *** LARGE SPILLS *** ELIMINATE POTENTIAL SOURCES OF
IGNITION. WEAR APPROPRIATE RESPIRATOR AND OTHER PROTECTIVE CLOTHING. SHUT OFF
SOURCE OF LEAK ONLY IF SAFE TO DO SO. DIKE AND CONTAIN. REMOVE WITH VACUUM TRUCKS
OR PUMP TO STORAGE/SALVAGE VESSELS. SOAK UP RESIDUE WITH AN ABSORBENT SUCH AS
CLAY, SAND, OR OTHER SUITABLE MATERIAL; PLACE IN NON-LEAKING CONTAINERS AND SEAL
TIGHTLY FOR PROPER DISPOSAL. FLUSH AREA WITH WATER TO REMOVE TRACE RESIDUE;
DISPOSE OF FLUSH SOLUTION AS ABOVE. *** SMALL SPILLS *** TAKE UP WITH AN ABSORBENT