User Manual
Table Of Contents
- Contents
- Safety information
- Note Ex area
- Quick start
- Quick start with the PC
- Quick start with adjustment module MINICOM
- 1 Product description
- 1.1 Function
- 1.2 Application features
- 1.3 Adjustment
- 1.4 Antennas
- 2 Types and versions
- 2.1 Survey
- 2.2 Configuration of measuring systems
- 3 Technical data
- 3.1 Technical data
- 3.2 Approvals
- 3.3 Dimensions
- 4 Mounting and installation
- 4.1 General installation instructions
- 4.2 Measurement of liquids
- 4.3 Measurement in standpipe (surge or bypass tube)
- 4.4 False echoes
- 4.5 Common installation mistakes
- 5 Electrical connection
- 5.1 Connection and connection cable
- 5.2 Connection of the sensor
- 5.3 Connection of the external indicating instrument VEGADIS 50
- 6 Setup
- 6.1 Adjustment methods
- 6.2 Adjustment with PC
- 6.3 Adjustment with adjustment module MINICOM
- 6.4 Adjustment with HART® handheld
- 7.2 Error codes
- 7 Diagnostics
- 7.1 Simulation
16 VEGAPULS 42 and 44 – 4 … 20 mA
Type code
PS 42 .XX X X X XXX X X
K - Plastic housing PBT, M20 x 1,5 cable entry
N - Plastic housing PBT,
1
/
2
“ NPT cable entry
A - Aluminium housing, M20 x 1,5 cable entry
D - Aluminium housing,
1
/
2
“ NPT cable entry in Exd connection
housing
V - Seal of the antenna system: Viton
A - Seal of the antenna system: Kalrez
G - Process fitting G 1
1
/
2
A
N - Process fitting 1
1
/
2
“ NPT
ABC- Process fitting DN 50 PN 16
BBE- Process fitting DN 80 PN 16
CBG- Process fitting DN 100 PN 16
DBG- Process fitting DN 150 PN 16
ARC- Process fitting ANSI 2“ 150 psi
BRE- Process fitting ANSI 3“ 150 psi
CRG- Process fitting ANSI 4“ 150 psi
DRG- Process fitting ANSI 6“ 150 psi
YYY- Process fitting on request
X - without display
A - with integrated display
X - without adjustment module MINICOM
B - with adjustment module MINICOM (mounted)
B - 20 … 72 V DC; 20 … 250 V AC; 4 … 20 mA, HART
®
(four-wire)
D - Two-wire (loop powered), 4 … 20 mA, HART
®
E - Supply via signal conditioning instrument
G - Segment coupler for Profibus PA
XX - FTZ (standard telecommunication approval Germany)
AX - Approval in Ex-Zone 1, EEx ia IIC T6
CX - Approval in Ex-Zone 0, EEx ia IIC T6
BX - Approval in Ex-Zone 1 (Exd connection housing)
DX - Approval in Ex-Zone 0 (Exd connection housing)
Type 42: with screw-on process fitting
Type 44: instrument series with flange process fitting
PS: Series 40 radar sensors
Types and versions