User's Manual

4 Insert the cable into the sensor through the cable entry
Fig. 13: Connection steps 4 and 5
5 Insert the wire ends into the terminals according to the wiring plan
Information:
Solid cores as well as exible (stranded) cores with wire end sleeves
are inserted directly into the terminal openings. If you are using exible
cores without end sleeves, press with a small screwdriver on the
terminal, the terminal opening is freed. When the screwdriver is
released, the terminal closes again.
6 Check the hold of the wires in the terminals by lightly pulling on
them
7 Connect the screen to the internal ground terminal, connect the
outer ground terminal to potential equalisation
8 Tighten the compression nut of the cable entry. The seal ring must
completely encircle the cable
9 Screw the housing cover on
The electrical connection is nished.
Information:
The terminal block is pluggable and can be removed from the
electronics. For this purpose, lift the terminal block with a small
screwdriver and pull it out. When inserting the terminal block again,
you should hear it snap in.
20 VEGAMIP R61 - Relay
5 Connecting to power supply
35786-EN-100531