User's Manual

By means of the LED indicating board, you can adjust the switching
delay.
Push the two keys (7) and (8) simultaneously for approximately 2 s
until the LED indication ashes.
With the two keys you can select the requested switching delay
according to the following illustration.
The switching delay can be adjusted in seven steps between 100 ms
and 20 s.
200
ms
100
ms
500
ms
1 s 2 s 5 s 20 s
Fig. 32: Adjust switching delay - LED indication ashes
If the indication moves to the right, the switching delay will be longer, to
the left shorter.
The indication returns automatically to the indication of the actual
receiving level after approximately 10 s.
If possible, you can simulate a lling between emitting and receiving
unit by using the hand or a metal sheet and check if the switching point
is adjusted correctly. If the relay control lamp changes the switching
condition, then the switching function is correct.
Switching delay
Simulation
VEGAMIP R61 - Relay 27