User Manual

Fig. 10: Alignment in liquids
The mounting location of the radar sensor should be a place where no
other equipment or xtures cross the path of the microwave signals.
Vessel installations, such as e.g. ladders, limit switches, heating
spirals, struts, etc., can cause false echoes and impair the useful echo.
Make sure when planning your measuring site that the radar sensor
has a "clear view" to the measured product.
In case of existing vessel installations, a false echo storage should be
carried out during setup.
If large vessel installations such as struts or supports cause false
echoes, these can be attenuated through supplementary measures.
Small, inclined sheet metal baes above the installations scatter the
radar signals and prevent direct interfering reections.
Fig. 11: Cover smooth proles with deectors
If there are agitators in the vessel, a false signal suppression should be
carried out with the agitators in motion. This ensures that the interfering
reections from the agitators are saved with the blades in dierent
positions.
Vessel installations
Agitators
VEGAPULS 62 4 20 mA/HART two-wire 17
4 Mounting
36503-EN-100607