User Manual

Fig. 12: Agitators
Through the action of lling, stirring and other processes in the vessel,
compact foams that damp the emitted signals considerably may form
on the product surface.
If foams are causing measurement err ors, the biggest possible radar
antennas, the electronics with increased sensitivity or low frequency
radar sensors (C band) should be u sed.
As an alternative, sens ors with guided microwave can be used. These
are unaected by foam generation and are best suited for such
applications.
When using a surge pipe in a vessel, inuences from vessel
installations and turbulences can be excluded. Under these prereq-
uisites, the measurement of products with low dielectric values
r
value 1.6) is possible. In very adhesive products, measurement in a
surge pipe is not recommended.
Foam generation
Measurement in a surge
pipe
18 VEGAPULS 62 4 20 mA/HART two-wire
4 Mounting
36503-EN-100607