User Manual

Information:
The connection of an external indicating and adjustment unit is not
possible with this double chamber housing.
4...20mA
2
3
1
2
+
( )
(-)
1
Fig. 21: Connection compartment, double chamber housing
1 Voltage supply/Signal output
2 For indicating and adjustment module or interface adapter
3 Ground terminal for connection of the cable screen
5.5 Wiring plan with double chamber housing Ex d
5 6 7
8
1
2
+
( )
(-)
31
2
4...20mA
Fig. 22: Electronics compartment, double chamber housing
1 Internal connection to the connection compartment
2 For indicating and adjustment module or interface adapter
3 Internal connection to the plug connector for external indicating and
adjustment unit (optional)
Connection compart-
ment
Electronics compart-
ment
VEGAPULS 62 4 20 mA/HART two-wire 29
5 Connecting to power supply
36503-EN-100607