Proceed as follows:
1 Select with [->] the menu item max. adjustment and conrm with
[OK].
2 Prepare the percentage value for editing with [OK] and set the
cursor to the requested position with [->].
3 Set the requested percentage value with [+] and save with [OK].
The cursor jumps now to the distance value.
4 Enter the appropriate distance value in m (corresponding to the
percentage value) for the full vessel. Keep in mind that the max.
level must lie below the min. distance to the antenna edge.
5 Save settings with [OK]
Further settings
The following circumstances cause interfering reections and can
inuence the measurement:
l High sockets
l Vessel installations such as struts
l Agitators
l Buildup or welded joints on vessel walls
Note:
A false signal suppression detects, marks and saves these false
signals so that they are no longer taken into account for level
measurement.
This should be done with a low level so that possible interfering
reections can be detected.
Proceed as follows:
1 Select the menu item "Additional settins" with [->] and conrm with
[OK]. With [->] you have to select the menu item "False signal
suppression" and conrm with [OK].
Setup/Max. adjustment
Further set-
tings/False sig-
nal suppression
VEGAPULS 62 4 20 mA/HART two-wire 37
6 Set up with the indicating and adjustment module