Ambient conditions
Ambient, storage and transport temperature -40 … +80 °C (-40 … +176 °F)
Process conditions
For the process conditions, you also have to note the specifications on the type label. Always the
lowest value is applicable.
Seal Antenna impedance co-
ne
Process temperature (measured on the process
fitting)
FKM (Viton) PTFE -40 … +130 °C (-40 … +266 °F)
PTFE -20 … +200 °C (-4 … +392 °F)
PP -40 … +80 °C (-40 … +176 °F)
PEEK -40 … +200 °C (-40 … +392 °F)
FFKM (Kalrez 6375) PFFE -20 … +130 °C (-4 … +266 °F)
PFFE -20 … +200 °C (-4 … +392 °F)
PP -15 … +80 °C (+5 … +176 °F)
PEEK -20 … +250 °C (-4 … +482 °F)
FFKM (Kalrez 2035) PFFE -15 … +130 °C (5 … +266 °F)
PTFE -15 … +200 °C (5 … +392 °F)
PEEK -15 … +210 °C (5 … +410 °F)
FFKM (Kalrez 6230) PFFE -15 … +130 °C (5 … +266 °F)
PTFE -15 … +200 °C (5 … +392 °F)
PEEK -15 … +250 °C (5 … +482 °F)
Graphite Ceramic -200 … +450 °C (-328 … +842 °F)
Vessel pressure - horn antenna
- Antenna impedance cone PTFE -1 … 40 bar (-100 … 4000 kP a/-14.5 … 580 psig)
- Antenna impedance cone PP -1 … 3 bar (-100 … 300 kPa/-14.5 … 43.5 psig)
- Antenna impedance cone PEEK -1 … 100 bar (-100 … 10000 kPa/-14.5 … 1450 ps ig)
- Antenna impedance cone ceramic -1 … 160 bar (-100 … 16000 kPa/-14.5 … 2320 psig)
Vessel pressure - parabolic antenna -1 … 6 bar (-100 … 6000 kPa/-14.5 … 870 psig)
Vessel pressure relating to the flange nom-
inal stage
see supplementary instructions manual "Flanges
according to DIN-EN-ASME-JIS"
Vibration resistance
4)
- Horn antenna mechanical vibrations with 4 g at 5 … 100 Hz
- Parabolic antenna mechanical vibrations with 1 g at 5 … 100 Hz
4)
Tested according to the guidelines of German Lloyd, GL directive 2.
VEGAPULS 62 • 4 … 20 mA/HART two-wire 59
11 Supplement
36503-EN-100607