User Manual

- Housing ABS
- Inspection window Polyester foil
Integrated clock
Date format Day.Month.Year
Time format 12 h/24 h
Time zone Ex factory CET
Electronics temperature measurement
Resolution 1 °C (1.8 °F)
Accuracy ±1 °C (1.8 °F)
Voltage supply
Operating voltage
- Non-Ex instrument 9.6 36 V DC
- Ex-ia instrument 9.6 30 V DC
- Ex-d-ia instrument 14 36 V DC
Operating voltage with lighted indicating and adjustment module
- Non-Ex instrument 16 36 V DC
- Ex-ia instrument 16 30 V DC
- Ex-d-ia instrument 20 36 V DC
Interpolation protection Available
Permissible residual ripple - Non-Ex, Ex-ia instrument
- for 9.6 V
< U
N
< 14 V 0.7 V
e
(16 400 Hz)
- for 18 V
< U
N
< 36 V 1 .0 V
e
(16 400 Hz)
Permissible residual ripple - Ex-d-ia instrument
- for 18 V
< U
N
< 36 V 1 V
e
(16 400 Hz)
Load see diagram
62 VEGAPULS 62 4 20 mA/HART two-wire
11 Supplement