User Manual

l Electronics with increased sensitivity type PS60HS, modication
status 22
The scope of delivery encompasses:
l Radar sensor
l Documentation
- this operating instructions manual
- Safety Manual (SIL) VEGAPULS 62 (optional)
- Operating instructions manual "Indicating and adjustment
module" (optional)
- Operating instructions "Radio module" (optional)
- Supplementary instructions manual "Heating for indicating and
adjustment module" (optional)
- Supplementary instructions manual "Plug connector for con-
tinuously measuring sensors" (optional)
- Ex-specic "Safety instructions" (with Ex versions)
- if necessary, further certicates
3.2 Principle of operation
The version with "Horn antenna ø 40 mm (1.575 in)" is particularly
suitable for small tanks and process vessels for measurement of
virtually all products.
The version with "Horn antenna ø 48 95 mm (1.89 3.74 in)" is
particularly suitable for storage tanks and process vessels, for
measurement of products such as solvents, hydrocarbons and fuels
under most dicult pr ocess conditions.
The version with Parabolic antenna is particularly suitable for
measurement of products with low ε
r
value at great measuring
distances.
The electronics version with increased sensitivity enables the use of
the instrument also in applications with very poor reective properties
or products with low ε
r
value.
The antenna of the radar sensor emits short radar pulses with a
duration of approx. 1 ns. These pulses are reected by the product
and received by the antenna as echoes. The running time of the radar
pulses from emission to reception is proportional to the distance and
hence to the level. The determined level is converted into an
appropriate output signal and outputted as measured value.
3.3 Packaging, transport and storage
Your instrument was protected by packaging during transport. Its
capacity to handle normal loads during transport is assured by a test
according to DIN EN 24180.
Scope of delivery
Application area
Functional principle
Packaging
8 VEGAPULS 62 4 20 mA/HART two-wire
3 Product description
36503-EN-100607