User's Manual

46
6 Set up with the display and adjustment module
VEGAPULS 62 • 4 … 20 mA/HART - two-wire
36503-EN-161221
Vessel:
Lateral outlets and inlets
Joinslikeanges,weldjoints
Shifting of the running time in the tube
Process/measurement conditions:
Condensation
Buildup
Separation of oil and water possible
Overllingintotheantennapossible
Properties, sensor:
Measurementspeedoptimizedthroughlittleaveraging
Entering the tube inside diameter takes the running time shift
into consideration
Echo detection sensitivity reduced
False signal suppression recommended
Plastic tank:
Device mounting is limited to directly downward positioning only, and
cannot be operated while moving or in a ANY moving container. Only
the following antennas are approved for use in plastic containers:
75mmlledhornantenna,75mmhornantenna,75mmplastichorn
antenna, 95 mm horn antenna.
Vessel:
Instrumentxmountedorbuiltin
Measurement through the vessel top, if appropriate to the
application
With empty vessel, the measurement can go through the bot-
tom
Process/measurement conditions:
Condensation on the plastic ceiling
In outdoor facilities, water and snow on vessel top possible
Properties, sensor:
False signals outside the vessel are not taken into consideration
False signal suppression recommended
Transportable plastic tank:
Device mounting is limited to directly downward positioning only, and
cannot be operated while moving or in a ANY moving container. Only
the following antennas are approved for use in plastic containers:
75mmlledhornantenna,75mmhornantenna,75mmplastichorn
antenna, 95 mm horn antenna.
Vessel:
Materialandthicknessdierent
Measurement through the vessel top
Process/measurement conditions:
Measured value jump with vessel change
Properties, sensor:
Quickadaptationtochangingreectionconditionsduetoves-
sel change
False signal suppression required