4 Mounting
VEGAPULS 64 • 4 … 20 mA/HART - two-wire
51141-EN-160616
Fig. 13: Mounting of the radar sensor with inowing medium
The socket piece should be dimensioned in such a way that the an-
tenna end protrudes at least 5 mm (0.2 in) out of the socket.
ca. 5 mm
Fig. 14: Recommended socket mounting
Ifthereectivepropertiesofthemediumaregood,youcanmount
VEGAPULS 64 on sockets which are higher than the length of the
antenna.Youwillndrecommendedvaluesforsocketheightsinthe
following illustration. The socket end should be smooth and burr-free,
if possible also rounded. After installation you must carry out a false
signal suppression.
d
h
Fig. 15: Deviating socket dimensions
Information:
When mounting on longer sockets, we recommend carrying out a
false signal suppression (see chapter "Parameter adjustment").
The below charts specify the max. socket length h depending on the
diameter d.
Socket diameter d Socket length h
40 mm ≤200mm
Socket with threaded
tting