4 Mounting
4.1 General instructions
Select an installation position you can easily reach for
mounting and connecting as well as later retrotting of an
indicating and adjustment module. The housing can be rotated
by 330° without the use of any tools. You can also install the
indicating and adjustment module in four dierent positions
(each displaced by 90°).
Warning:
The housing must not be used to screw in the instrument!
Applying tightening force on the housing can damage its
internal mechanical parts.
Use the recommended cables (see chapter "Connecting to
power supply") and tighten the cable gland.
You can give your VEGAPULS 62 additional protection against
moisture penetration by leading the connection cable down-
ward in front of the cable entry. Rain and condensation water
can thus drain o. This applies mainly to mounting outdoors, in
areas where moisture is expected (e.g. by cleaning processes)
or on cooled or heated vessels.
Fig. 2: Measures against moisture penetration
The reference plane for the measuring range is the lower edge
of the ange or the seal surface of the thread.
Installation position
Screwing in
Moisture
Measuring range
14 VEGAPULS 62 - 4 ... 20 mA/HART
Mounting
28435-EN-060317