User's Manual

Table Of Contents
ment. A false echo storage detects and marks these false
echoes, so that they are no longer taken into account for the
level measurement. A false echo memory should be created
with empty vessel so that all potential interfering reections will
be detected.
False signal suppression
Change now?
Proceed as follows:
1 Move from the measured value display to the main menu
by pushing [OK].
2 Select the menu item "Service" with [->] and conrm with
[OK]. Now the menu item "False signal suppression" is
displayed.
3 Conrm "False signal suppression - Change now" with
[OK] and select in the below menu "Create new". Enter the
actual distance from the sensor to the product surface. All
false signals in this area are detected by the sensor and
saved after conrming with [OK] .
Note:
Check the distance to the product surface, because if an
incorrect (too large) value is entered, the existing level will be
saved as false signal. The lling level would then no longer be
detectable in this area.
This function enables to read out parameter adjustment data
as well as write parameter adjustment data into the sensor via
the indicating and adjustment module PLICSCOM. A descrip-
tion of the function is available in the operating instructions
manual "Indicating and adjustment module PLICSCOM".
The following data are read out or written with this function:
l Measured value presentation
l Adjustment
l Medium
l Standpipe inner diameter
8)
l Vessel form
l Damping
l Linearization curve
l Sensor-TAG
8)
8)
With standpipe versions.
Copy sensor data
Setup with the indicating and adjustment module PLICSCOM
VEGAPULS 62 - 4 ... 20 mA/HART 41
28435-EN-060317