User Manual
FL SWITCH SFN…
2732_en_D PHOENIX CONTACT 5
Maximum transmission length 550 m (50/125 µm)
220 m (62.5/125 µm)
Transmission power
Minimum
Maximum
-9.5 dBm
-4 dBm
Receiver sensitivity
Minimum
Maximum
-17 dBm
-3 dBm
Properties of 1000 Mbps single mode
Transmission rate 1.25 Gbps full duplex
Wavelength 1310 nm
Maximum transmission length
FL SWITCH 6GT/2LX
FL SWITCH 6GT/2LX-20
10 km (9/125 µm)
20 km (9/125 µm)
Transmission power
Minimum
Maximum
-10 dBm
-3 dBm
Receiver sensitivity
Minimum
Maximum
-24 dBm
-0 dBm
Alarm Contacts (FL SWITCH SFN…GT… only)
Voltage 24 V DC typical
Current carrying capacity 100 mA maximum including inrush
Interfaces (Continued)
Mechanical Tests
Shock test according to IEC 60068-2-27 Operation: 25g, 11 ms period, half-sine shock pulse
Storage/transport: 50g, 11 ms period, half-sine shock pulse
Vibration resistance according to IEC 60068-2-6 Operation/storage/transport: 5g, 150 Hz, Criterion 3
Free fall according to IEC 60068-2-32 1 m
Conformance With EMC Directives
Developed according to IEC 61000-6-2
IEC 61000-4-2 (ESD) Criterion B
IEC 61000-4-3 (radiated-noise immunity) Criterion A
IEC 61000-4-4 (burst) Criterion A
IEC 61000-4-5 (surge) Criterion B
IEC 61000-4-6 (conducted noise immunity) Criterion A
IEC 61000-4-8 (noise immunity against magnetic fields) Criterion A
EN 55022 (noise emission) Class A
Approvals
FL SWITCH SFN…TX… switch c u ROHS EEE 2002/95/EC, WEEE 2002/96/EC,
U Class I, Division 2, Groups A, B, C, D Temp Code T5
installed in minimum IP54 enclosure
FL SWITCH SFN…GT… switch c u ROHS EEE 2002/95/EC, WEEE 2002/96/EC
U Class I, Division 2, Groups A, B, C, D Temp Code T4
installed in minimum IP54 enclosure