TheMINITRAC31requiresthisinformationforthedecaycompensa-
tion. An annual recalibration is hence not necessary.
Entertherequestedparametersviatheappropriatekeys,saveyour
settingswith[OK]andjumptothenextmenuitemwiththe[ESC] and
the [->] key.
Enter here, the respective application.
Thismenuitemenablesadaptationofthesensortotherequestedap-
plication.Youcanchoosebetweenthefollowingapplications:"Level",
"Density", "Limit level", "X-ray alarm" or "Real value correction".
With this menu item you safeguard the sensor parameters against
unauthorizedorunintentionalmodications.
This menu item is described in the operating instructions manual
"Display and adjustment module".
6.7 Parameter adjustment/Real value correction
To correct a level measurement, a real value correction can be carried
outwhenacertainlevelisreached.Thisisforexamplenecessaryin
caseofrecurringbuilduponthevesselwall.
The level measurement can thus be reset to the correct real value.
The level measuring instrument acts as Master and the MINITRAC 31
operates as Slave.
Firstofall,denethefunctionoftheSlaveinstrumentbeforeyou
denetheMasterinstrument.TheMasterinstrumentcanthusimme-
diatelyrecognizetheconnectedSlave.
Forthispurpose,theSlaveinstrumentmustbedenedas"Realvalue
correction". Select under the menu item "Setup/Application" the func-
tion "Real value correction".
Youcansettheaddress(MGC)ontheSlaveinstrumentatwill.Only
the address "0 - 0" is reserved for the Master instrument.
The Master instrument must have the function "Level". For this
purpose, select under the menu item "Setup/Application" the function
"Level".
Set the address setting (MGC) on the Master instrument to "0 - 0".
You have to enter the address of the Slave instrument in the list of
the Master instrument. This function is not possible in the display and
adjustmentmodule.TodothisyouneedPACTwarewiththerespective
DTM.
Setup - Application
Lock setup - adjustment
Real value correction