Operating Instructions VEGADIS 61 Document ID: 27720 Indication and adjustment
Contents Contents 1 About this document 1.1 1.2 1.3 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . General instructions . . . . . . . . . . . . . . . . . . . . . . . . . Instructions for installation . . . . . . . . . . . . . . . . . . . . . 11 11 Preparing the connection . . . . . . . . . . . . . . . . . . . . . Connection procedure. . . . . . . . . . . . . . . . . . . . . . .
Contents Supplementary documentation 27720-EN-120329 Information: Supplementary documents appropriate to the ordered version come with the delivery. You can find them listed in chapter "Product description".
1 About this document 1 About this document 1.1 Function This operating instructions manual provides all the information you need for mounting, connection and setup as well as important instructions for maintenance and fault rectification. Please read this information before putting the instrument into operation and keep this manual accessible in the immediate vicinity of the device. 1.2 Target group This operating instructions manual is directed to trained qualified personnel.
2 For your safety 2 For your safety 2.1 Authorised personnel All operations described in this operating instructions manual must be carried out only by trained specialist personnel authorised by the plant operator. During work on and with the device the required personal protective equipment must always be worn. 2.2 Appropriate use VEGADIS 61 is an external indicating and adjustment unit for VEGA plics® sensors. You can find detailed information on the application range in chapter "Product description".
2 For your safety 2.5 Safety label on the instrument The safety approval markings and safety tips on the device must be observed. 2.6 CE conformity The device fulfills the legal requirements of the applicable EC guidelines. With the CE mark, we provide confirmation of successful testing. You can find the conformity certificate in the download section of our homepage. 2.7 NAMUR recommendations NAMUR is the automation technology user association in the process industry in Germany.
3 Product description 3 Product description 3.
3 Product description Type label The type label on the housing contains the most important data for identification and use of the instrument: 1 11 10 2 3 9 8 4 5 6 7 Fig.
3 Product description Application examples 2 3 2 5 4 1 4 Fig. 3: Connection of VEGADIS 61 to the sensor. The measured value indication and sensor adjustment are carried out via the integrated indicating and adjustment module 1 2 3 4 5 Voltage supply/Signal output sensor Sensor Connection cable VEGADIS 61 - Sensor VEGADIS 61 Indicating/adjustment module 2 3 2 5 4 1 4 6 Fig. 4: Connection of VEGADIS 61 to the sensor.
3 Product description Connection The VEGADIS 61 is connected with a four-wire cable to the sensor. Via this cable, the communication and power supply of VEGADIS 61 is carried out through the sensor. Additional external energy is not required. Permissible cable lengths, see chapter "Technical data". 3.3 Packaging, transport and storage Packaging Your instrument was protected by packaging during transport. Its capacity to handle normal loads during transport is assured by a test according to DIN EN 24180.
4 Mounting 4 Mounting 4.1 General instructions Mounting position VEGADIS 61 functions in any installation position. The housing can be rotated by 330° without the use of any tools. Moisture Use the recommended cables (see chapter "Connecting to power supply") and tighten the cable gland. You can give your instrument additional protection against moisture penetration by leading the connection cable downward in front of the cable entry. Rain and condensation water can thus drain off.
4 Mounting Carrier rail mounting VEGADIS 61 for mounting on carrier rail is supplied with a mounting adapter. 1 2 Fig. 7: VEGADIS 61 for carrier rail mounting 1 2 Tube mounting Adapter plate with screw M4 x 6 Carrier rail VEGADIS 61 for tube mounting is supplied with a meas. instrument holder and four screws M5 x 12 as mounting accessory. The meas. instrument holder is mounted to the socket of VEGADIS 61. 3 1 2 Fig.
5 Connecting to the sensor 5 Connecting to the sensor 5.1 Preparing the connection Safety instructions Always keep in mind the following safety instructions: l 4 … 20 mA/HART sensor Connect only in the complete absence of line voltage VEGADIS 61 is connected to the sensor with standard four-wire cable with screen. Use cable with round cross-section. A cable outer diameter of 5 … 9 mm (0.2 … 0.35 in) ensures the seal effect of the cable gland.
5 Connecting to the sensor 8 Press down the opening levers of the terminals, you will hear the terminal spring closing 9 Check the hold of the wires in the terminals by lightly pulling on them 10 Connect the screen to the ground terminal 11 Connect the ground terminal outside on the housing according to specification (low impedance) 12 Tighten the compression nut of the cable entry. The seal ring must completely encircle the cable 13 Screw the housing cover back on The electrical connection is finished.
5 Connecting to the sensor 5.3 Wiring plan Electronics and connection compartment 1 2 3 Display I2C 5 6 7 8 4 Fig. 10: Electronics and connection compartment 1 2 3 4 Contact pins for the indicating and adjustment module Spring-loaded terminals for connection to the sensor Plug connector for interface converter Ground terminal for connection of the cable screen Wiring plan 4 … 20 mA/ HART Display 5 6 7 8 4 1 2 27720-EN-120329 Fig.
5 Connecting to the sensor Connection via standard cable Connection between VEGADIS 61 and sensor is carried out according to the chart: VEGADIS 61 Sensor Terminal 5 Terminal 5 Terminal 6 Terminal 6 Terminal 7 Terminal 7 Terminal 8 Terminal 8 Connection via ready-made cable with 4-pin socket M12 x 1 Connection between VEGADIS 61 and sensor with 4-pin plug M12 x 1 is carried out according to the following chart.
5 Connecting to the sensor Wire colour VEGADIS 61 Black Terminal 5 Terminal 6 Terminal 7 Brown Terminal 8 27720-EN-120329 White Blue VEGADIS 61 17
6 Set up with the indicating and adjustment module 6 Set up with the indicating and adjustment module 6.1 Short description Function/Configuration The indicating and adjustment module is used for measured value display, adjustment and diagnosis.
6 Set up with the indicating and adjustment module Fig. 13: Installation of the indicating and adjustment module 6.3 Adjustment system 2 1 1.1 3 Fig.
6 Set up with the indicating and adjustment module Key functions Adjustment system l [OK] key: - Move to the menu overview - Confirm selected menu - Edit parameter - Save value l [->] key to select: - Menu change - Select list entry - Select editing position l [+] key: - Change value of the parameter l [ESC] key: - interrupt input - Return to higher-ranking menu The sensor is adjusted via the four keys of the indicating and adjustment module. The LC display indicates the individual menu items.
7 Maintenance and fault rectification 7 Maintenance and fault rectification 7.1 Maintenance If the instrument is used properly, no special maintenance is required in normal operation. 7.2 Remove interferences Reaction when malfunctions occur The operator of the system is responsible for taking suitable measures to rectify faults. 24 hour service hotline Should these measures not be successful, please call in urgent cases the VEGA service hotline under the phone no. +49 1805 858550.
8 Dismounting 8 Dismounting 8.1 Dismounting steps Warning: Before dismounting, be aware of dangerous process conditions such as e.g. pressure in the vessel, high temperatures, corrosive or toxic products etc. Take note of chapters "Mounting" and "Connecting to power supply" and carry out the listed steps in reverse order. 8.2 Disposal The instrument consists of materials which can be recycled by specialised recycling companies.
9 Supplement 9 Supplement 9.1 Technical data General data 316L corresponds to 1.4404 or 1.4435, 316Ti corresponds to 1.4571 Materials VEGADIS 61 - Housing plastic PBT, Alu die-casting, 316L - Inspection window in housing cover for indicating and adjustment module Polycarbonate (UL-746-C listed) - Ground terminal 316Ti/316L Materials mounting elements - Mounting plate Aluminium, 316L - Mounting adapter PVDF - Measuring instrument holder 316Ti/316L Weight without mounting element 0.35 kg (0.
9 Supplement - mounted into VEGADIS 61 without cover Materials - Housing - Inspection window IP 40 ABS Polyester foil Adjustment circuit Connection to the respective sensor Data transmission digital (I²C-Bus) Configuration connection cable 4-wire, screened Cable length max. - Sensors with software ≥ 4.0.0, hardware ≥ 2.0.0 50 m - Sensors with software ≤ 3.99, hardware< 2.0.
9 Supplement 9.2 Dimensions VEGADIS 61 housing ø 77 mm (3.03") ~ 59 mm (2.32") ø 77 mm (3.03") 128 mm (5.04") ø 80 mm (3.15") M20x1,5/ ½ NPT M20x1,5/ ½ NPT 1 112 mm (4.41") ~ 69 mm (2.72") 123 mm (4.84") ~ 69 mm (2.72") M20x1,5/ ½ NPT 2 3 ~ 116 mm (4.57") 125 mm (4.92") ø 84 mm (3.31") M20x1,5 M20x1,5/ ½ NPT 4 Fig.
9 Supplement 1 2 3 m 2m ") R3 17 / 64 (1 ~ 111mm (4 31/8") M6 60mm (2 23/64") 67mm (2 41/64") 11mm (7/16") 3mm (1/8") 16mm (5/8") 5mm (13/64") VEGADIS 61 mounting elements 70mm (2 3/4") 84mm (3 5/16") Fig.
9 Supplement 9.3 Industrial property rights VEGA product lines are global protected by industrial property rights. Further information see http://www.vega.com. Only in U.S.A.: Further information see patent label at the sensor housing. VEGA Produktfamilien sind weltweit geschützt durch gewerbliche Schutzrechte. Nähere Informationen unter http://www.vega.com. Les lignes de produits VEGA sont globalement protégées par des droits de propriété intellectuelle.
Printing date: VEGA Grieshaber KG Am Hohenstein 113 77761 Schiltach Germany Phone +49 7836 50-0 Fax +49 7836 50-201 E-mail: info.de@vega.com www.vega.com ISO 9001 All statements concerning scope of delivery, application, practical use and operating conditions of the sensors and processing systems correspond to the information available at the time of printing.