Manual

Proc
eed as follows:
1 Switch o power su pply
2 Unscrew housing cover of the electronics compartment
3 Remove the terminal blocks according to the operating instruc-
tions manual of the respective sensor
4 Loosen the two holding screws with a screwdriver (Torx size T 10
or Phillips size 4)
2
1
5 6 7
8
1
2
+
( )
(-)
Fig. 3: Loosening
the holding screws
1 Electronics module
2 Screws (2 pcs.)
5 Pull the previous electronics out by using the pull-out tool.
6 Insert the new electronics module carefully.
7 Insert the two hold screws and tighten them
8 Attach the terminal blocks according to the operating instructions
manual of the respective sensor
9 Screw the housing cover on
The electronics exchange is now nished.
As
a rule, the exchange of the electronics must be documented
internally when used in Ex applications.
Ele
ctronics module VEGAPULS series 60 9
4 M
ounting
36801-EN-101008