Section 7: Troubleshooting
Page 29
2. Once the potential air leak has
been discovered and corrected,
reat
tach the Hydro-Hot's Fuel
Return Line and attempt heater
restart. Does the Hydro-Hot's ex-
haust
system still sputter?
If the exhaust system is still sputtering:
Perform the air leak inspections
again,
until all air leaks have been
discovered
and corrected.
NOTE: If the Hydro-Hot's exhaust system still
produces white smoke after performing all of the
listed
checks, contact our Technical Department
at 1-800-685-4298 for additional assistance.
After turning the Diesel switch ON:
TS6
: The Hydro-Hot's exhaust system pro-
duces black smoke after ignition.
Q1: Is the Electronic Controller's Low Battery
Voltage Fault light illuminated?
A: If YES:
Perform each of the following
procedures as necessary until the
problem is resolved.
If NO:
Proceed
to Q2.
a. Remove the Electronic Controller's Faceplate.
Check
the DC battery voltage level at the
supply
batteries and at the Electronic
Controller's Battery Connections, reference
Figure 3. Both voltage readings should be
between
11.5 and 14.0 volts.
A: If the voltage level is within specs:
Continue troubleshooting.
If
the voltage level is out of specs:
Recharge and/or replace batteries, if
necessary.
Section 7.6
By Vehicle Systems
Diesel
Electri
c Engine
Preheat
Diesel-Burner’s
Indicator
Light
TM

 
R
Electronic Controller
Faceplate
Section 7.6,
continue
d
Section 7.5,
continue
d