Section 4: General Heater Information
4.3 Low Voltage Reset (Button)
The Hydro-Hot's Electronic Controller must be manually reset whenever the
Low Battery Voltage fault indicator light has been activated, reference
Figure 5. To reset the Electronic Controller, simply depress the "Low
Voltage Reset" button located on the Electronic Controller (use a thin
straight object to access the reset button through the small hole in the
faceplate).
4.4 Emergency Cutoff Indicator Light
This
indicator light will illuminate RED when either the 120 VAC Electric
Heating Element and/or the Diesel-Burner have automatically shutdown
due to a low water and antifreeze solution level inside the Hydro-Hot's
Boiler Tank, reference Figure 5. This fault will automatically reset when the
low level condition is corrected.
4.5 Heating Status Indicator Light
This
indicator light will illuminate GREEN whenever the Hydro-Hot's VDC /
VAC Control Thermostat is calling for heat, allowing the water and
antifreeze solution in the Hydro-Hot's Boiler Tank to be heated by either the
Diesel-Burner and/or the 120 VAC Electric Heating Element, reference
Figure 5. When this indicator light is off, no heat is being supplied to the
Hydro-Hot's Boiler Tank. Please note that this light will only be active if
either the Diesel and/or the Electric switch are turned ON, reference Figure
4.
NOTE:
The Hydro-Hot's VDC / VAC Control Thermostat will automat-
ically activate the Diesel-Burner and/or the 120 VAC Electric Heating
Element, only if the Diesel and/or Electric switch is in the ON position.
So to heat the motorhome / domestic hot water, simply choose the
desired heat source(s) and leave the switch(s) (i.e. Diesel and/or
Electric) ON.
4.6 Engine Preheat Pump Indicator Light
This
indicator light will illuminate GREEN whenever the Engine Preheat
Pump is operating, reference Figures 1 and 5. Please note that this light
will only be active if the Engine Preheat switch is ON in conjunction with
either the Diesel and/or the Electric switch, reference Figure 4. If this
indicator light illuminates RED, it indicates an electrical overload condition
(i.e. short) has occurred in this particular component's circuitry.
4.7 Circulation Pump #1 Indicator Light
This
indicator light will illuminate GREEN whenever Circulation Pump #1 is
operating, reference Figures 1 and 5. Please note that this light will only be
active if the Hydro-Hot is at normal operating temperature (i.e. between
160
��
��
�F and 190
��
��
�F) and if either Heating Zone #1 or #5 are calling for heat,
reference Figure 3. If this light illuminates RED, it indicates an electrical
overload condition (i.e. short) has occurred in this particular component's
circuitry.