User manual
DVM1090                 GB 2
CAD II  Overvoltage category II, pollution degree 2 per IEC1010-1 
CAT III  Overvoltage category III, pollution degree 2 per IEC1010-1 
2.2 Maintenance 
•  Do not remove the back cover while a voltage is being applied. Only a qualified technician should handle repairs. 
• 
Always disconnect the test leads from all current sources before opening the meter. 
•  Replace the battery when the 
 symbol is displayed. 
• 
Replace blown fuses with an identical one or a fuse with identical voltage and current ratings : F 200mA/250V 
(quick-acting, max. resistance 2Ω), F 10A/250V (“quick-acting”). 
•  Use a damp cloth and a mild detergent to clean the device. Never apply abrasives or solvents to the meter 
• 
Place the power switch in the OFF position when the device is not being used 
•  Remove the batteries to keep them from leaking if the device is to be stored for a prolonged period of time. 
3. Front Panel Description 
1. LCD display 
2.  L/C button : press this button prior to each individual 
capacitance and inductance measurement in order to 
calibrate the device. 
3.  Power button (
) 
4.  Range selector : used to select the desired function and 
range 
5. Front panel 
6. Battery cover 
7. 10A jack 
8. Capacitor and 
Ω
, °C, A, V, Hz and H-jack 
9. COM jack 
10. DC/AC button (DC/AC) : used for AC/DC voltage and 
AC/DC current measurements. Place the button in the 
pressed-down position for AC current or voltage 
measurements or put it in the depressed position for DC 
current and voltage measurements. 
11. Backlight button (LIGHT) 
12. Data-hold button (HOLD) 
 Low battery 
 Fuse 
 AC (alternating current) 
DC (direct current) 
buzzer for continuity 
AC or DC (alternating current or direct current) 