Operation Manual

10A
10mA
When measuring currents > 6A, max. 15s continuous measurement followed by a 15
minutes break between 2 measurements.
Overload Protection: 600mA range F0.63A/1000V 10A range fuse F10A/1000V
9.5. Resistance
Range
Resolution
Accuracy
600
0.1
(0.5% of rdg + 3 digits)
6k
1
(0.5% of rdg + 2 digits)
60k
10
600k
100
6M
1k
60M
10k
(1.5% of rdg + 5 digits)
Note: in range 600Ω, short circuit test leads to determine lead resistance, than
subtract this value from the measured value.
9.6. Diode and audible continuity test
Range
parameters
Built-in buzzer sounds if resistance < 30Ω
Forward test current(DC): ± 1mA
Reversed test voltage: ± 1.5Vdc
9.7. Capacitance
Range
Resolution
Accuracy
60nF
10pF
<10nF: ±(5.0% of (rdg - 50 digits) + 20 digits)
>10nF: ±(3.0% of rdg + 10 digits)
600nF
100pF
(5.0% of rdg +10 digits)
6µF
1nF
60µF
10nF
300µF
100nF
9.8. Temperature
Range
Resolution
Accuracy
-55°C ~ 0°C
0.1°C
±(5.0% of rdg + 4°C)
1°C ~ 400°C
±(1.0% of rdg + 3°C)
401°C ~ 1,000°C
1°C
±(2.0% of rdg)
Note: thermocouple errors not included
9.9. Frequency
Range
Resolution
Accuracy
Logic
(1Hz~1MHz)
Linear
(6Hz~10KHz)
99.99Hz
0.01Hz
±(0.1% of rdg + 3 digits)
±(0.05% of rdg + 8 digits)
999.9Hz
0.1Hz
9.999kHz
1Hz
99.99kHz
10Hz
N.A.
999.99kHz
100Hz
Use this device with original accessories only. Velleman nv cannot be held
responsible in the event of damage or injury resulted from (incorrect) use
of this device. For more info concerning this product and the latest version
of this user manual, please visit our website www.velleman.eu. The
information in this manual is subject to change without prior notice.
© COPYRIGHT NOTICE
This manual is copyrighted. The copyright to this manual is owned by Velleman nv. All
worldwide rights reserved. No part of this manual may be copied, reproduced, translated or reduced
to any electronic medium or otherwise without the prior written consent of the copyright holder.