User Manual

HAA263D
02 (15/11/2013) VELLEMAN
4
PART. 2 ON Partition 2 armed
OFF Partition 2 disarmed
Flash During Exit Delay
FORCED TO ARM
ON System will be forced to arm if the faulty zone is not
cleared
OFF System armed normally
Flash System forced to arm with the faulty zone(s) bypassed
by the system
B. Zone status LEDs
ON Zone abnormal
OFF Zone normal
Fast flashing Zone was or still is in alarm mode
Fast flashing, 3x with
stopping interval
Zone was in alarm mode and is stored in alarm memory. System
is disarmed
Slow flashing Zone is bypassed
C. Control key buttons description
There are 14 buttons for code entry and function confirmation
0 ~ 9 Numeric buttons for code entry
* # For function confirmation
HOME For home mode arming and programming
BYPASS For (temporarily) bypassing zones while arming system
D. Audible keypad notifications
1 short beep Successful key entry
2 short beeps Successful code entry for a specific function
5 short beeps
Unsuccessful code entry
Code entry time expired (Maximum Allowable
Time:10 seconds/digit, 60 seconds/code)
1 long beep Exit delay expired, system is armed
1 short beep/30 seconds Battery low or AC power failure
Continuous short beeps at 0.5
second interval
Beeping increases to 4 beeps/second
at the last 10 seconds
1 long beep at the end of the period
During the Exit delay, Entry delay and System
Standby period
4 short beeps with 1 second interval After an alarm condition before the system is
disarmed
7. Programming
a. Set programming mode
Make sure the system is in disarmed mode and the alarm memory is empty.
Enable programming mode with the master code. Key in the master code, followed by . The
system generates 2 beeps for successful and 5 beeps for unsuccessful code entry.
Factory default master code is 1234. For security reasons, it is strongly advised to replace this
master code with a personal code.
The PROGRAM LED is on and the system stops all its detection activities.