LCD
1 laser ON 5 single mode
2 reference level top 6 battery status
3 reference level bottom 7 memory address
4 measuring function 8 device error
area 9 max./min. indication
volume 10 first value + unit
1
st
indirect measurement 11 second value + unit
2
nd
indirect measurement 12 last measurement or
calculation result
6. Measuring conditions
Measuring range
The measuring range is limited to 50m.
In dark environments or at night this range may increase.
In very light environments or when a surface has very poor reflective
properties, use a target plate.
Target surfaces
Measuring errors will occur when pointing at colourless liquids (e.g. water)
or glass, Styrofoam or similar semi-transparent surfaces.
Aiming at very shiny objects will deflect the laser beam which will lead to
errors.
Measuring towards non-reflective dark surfaces may increase the
measuring time.
Do not aim the meter directly into the sun or other bright light source.
7. General functions
Refer to the illustrations on pages 2 and 3 of this manual.
Make sure batteries are present inside the device. Refer to §11.
Switching ON/OFF
Press the ON/measuring button [a] to switch the device and laser on.
Press and hold the clear/OFF button [j] to switch the device off.
Note: the laser will automatically switch of after 30s, the device will
switch off after 3 minutes of inactivity.
Clear button
Press the clear/OFF button [j] to cancel the last action.
Reference level
Press the reference button [h] to switch the reference level between
top [2] and bottom [3] (refer to illustration B). The device produces a
warning beep when the setting is changed.
[2] measuring starts at the top of the meter
[3] measurement includes length of meter (default)