Installation Guide

6 VELUX
®
ENGLISH:
Important information/Warnings
Please keep instructions for future reference and hand them over to any new
user.
Electrical connection (VSE only)
It is customer's responsibility:
To contact a qualified electrical installer.
To assure that the electrical installation is adequate and in conformity with
National Electrical Code, ANSI/NFPA 70 - latest edition*, and all local codes
and ordinances. Failure to do so could result in fire, electrical shock, other seri-
ous personal injury or death.
Electrical Shock Hazard (VSE only)
The skylight operator is a class I product.
• Disconnect power to the junction or outlet box before servicing the skylight.
Do not have a fuse in the neutral circuit. This could result in a fire, electrical
shock or other personal injury.
To reduce the risk of fire, personal injury and death:
Do not install the skylight in a location or at a height where unsupervised
children may be present.
Always switch o power to the skylight operator at the service panel when
connecting the skylight, when installing accessories and whenever the opera-
tor cover is removed.
• On suspicion of malfunction, switch o power and call for service.
Safety
The skylight is to be installed more than 8 feet (2.44 m) above the floor.
The skylight can be used by persons (aged 8 years and above) with sucient
experience and knowledge if they have been given instruction concerning its
safe use and understand the hazards involved. Cleaning and user maintenance
must not be made by unsupervised children.
Children must not play with the skylight and its electrical products. The
control should be kept out of reach of children. Do not allow children near an
open skylight.
Before operating ensure that the skylight with electrical products can be oper-
ated without risk of damage to property or injury to people or animals.
For personal safety, never have head, hand, arm or any other body part out of
or through the opening of the skylight without first having switched o power.
If repair or adjustment work is needed, disconnect power and ensure that it
cannot be reconnected unintentionally.
It is recommended that a control be placed in the room where the skylight and
its electrical products have been installed.
Make sure that the insect screen is installed before putting the skylight into use.
Control:
FCC ID: XSG863878 and IC ID: 8642A-832794,
Certificate of Radio Equipment in Japan: No. 13215185
• Window operator (solar skylight operator):
FCC ID: XSG832876 and IC ID: 8642B-832876
• Window operator (electrical skylight operator):
FCC ID: XSG863765 and IC ID: 8642A-863765
This device complies with part 15 of the FCC and RSS-210 of the IC rules.
Operation is subject to the following two conditions: (1) This device may not
cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
This device has been tested and found to comply with the limits for a Class B
digital device, pursuant to part 15 of the FCC Rules. These limits are designed
to provide reasonable protection against harmful interference in a residential
installation.
This device generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this device does cause
harmful interference to radio or television reception, which can be determined
by turning the device o and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the device and receiver.
- Connect the device into an outlet on a circuit dierent from that to which the
receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Changes or modifications not expressly approved by the party responsible for
compliance could void the user's authority to operate the device.
FCC Radiation Exposure Statement: This device complies with FCC RF radia-
tion exposure limits set forth for an uncontrolled environment
The term "IC:" before the device certification number signifies that the Indus-
try Canada technical specifications were met.
Function
If the VSE rain sensor gets wet or the VSS acoustical rain sensor detects rain,
the skylight automatically closes.
Disabling the rain sensor while the skylight is open creates a risk of water to
the interior of the building.
If the rain sensor is activated, the skylight will close within approximately 30
seconds. If the skylight is activated with the remote control or another control,
it will take up to one minute until the skylight is completely closed. Therefore,
in case of sudden rain, water may enter the room before the skylight is closed.
In case of snow and/or ice, the operation of the skylight may be blocked result-
ing in damage to the skylight.
Product
The skylight has been designed for use with genuine VELUX products. Connec-
tion to or use with other products may cause damage, malfunction or injury.
Electrical products must be disposed of in conformity with all local codes,
ordinances, rules and regulations for electronic waste and not with household
waste.
Used batteries have to be disposed of in conformity with the relevant environ
mental regulations and ordinances.
• Expected lifetime of the control batteries: Approx 1 year.
• The packaging can be disposed of with usual household waste.
• Radio frequency band: 2.4 GHz.
Radio frequency range: 110 yards (100 m) free field. Depending on building
construction, the indoor range is approx 30 ft (10 m). However, constructions
with reinforced concrete, metal ceilings and plaster walls with steel members
may reduce the range.
Maintenance and service
Disconnect power before carrying out any maintenance, repair, adjustment
or service work to the skylight or products connected to it (including bat-
tery backup KLB 100, if installed) and ensure that it cannot be reconnected
unintentionally.
Maintenance and installation must be carried out in consideration of Health
and Safety at Work requirements.
There are no serviceable parts inside the skylight operator. Accessories are to
be connected according to VELUX installation instructions.
Spare parts are available through your VELUX sales company. Please provide
information from the data plate.
If you have any technical questions, please contact your VELUX sales com-
pany, see telephone list or www.velux.com.
* National Fire Protection Association, Batterymarch Park, Quincy Massachu-
setts 02269.
io-homecontrol
®
provides advanced and secure radio technology that is easy to install.
io-homecontrol
®
labelled products communicate with each other, improving comfort,
security and energy savings.
www.io-homecontrol.com