INSTALLATION INSTRUCTIONS HB0104 CC32I SERIES ! INTENDED FOR DOMESTIC COOKING ONLY ! READ AND SAVE THESE INSTRUCTIONS INSTALLER: LEAVE THIS MANUAL WITH HOMEOWNER. HOMEOWNER: USE AND CARE INFORMATION ON PAGES 13 AND 14. Venmar Ventilation ULC, 550 Lemire Blvd., Drummondville QC J2C 7W9 1-800-567-3855 REGISTER YOUR PRODUCT ONLINE AT: www.bnv.ca For additional information - visit www.venmar.ca 09023 rev.
! WARNING ! TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING*: 1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty. 1. SMOTHER FLAMES with a close-fitting lid, cookie sheet or metal tray, then turn off the burner.
- CC32I SERIES RANGE HOOD SYSTEMS - MODEL 639 (STANDARD 3¼” X 10” WALL CAP) MODEL 634 OR 644 (ROOF CAP) MODEL 643 (8” ROUND WALL CAP) 8” ROUND ADJUSTABLE ELBOW, OPTIONAL PLENUM (SUPPLIED WITH 09025 NON-DUCT KIT UPPER DECORATIVE FLUE 8” ROUND METAL FLEXIBLE MODEL 401 (STANDARD 3¼” X 10” DUCT) DUCT (SUPPLIED WITH 8” ROUND 09025 NON-DUCT KIT) STANDARD DUCT LOWER DECORATIVE FLUE ADAPTER/DAMPER 3¼” X 10” (SUPPLIED WITH HOOD) FOR HORIZONTAL ADAPTER/DAMPER 8” ROUND (SUPPLIED WITH HOOD) FOR VERTICAL
1. PREPARE THE INSTALLATION ! WARNING When performing installation, servicing or cleaning the unit, it is recommended to wear safety glasses and gloves. NOTE: Before proceeding to the installation, check the contents of the box. If items are missing or damaged, contact the manufacturer.
2. SELECT INSTALLATION TYPE (CONT'D) Refer to illustrations below to locate duct opening according to discharge type chosen (grey parts to be installed later). CL VERTICAL DISCHARGE 30” WIDTH HOOD OR NON-DUCTED INSTALLATION 36” WIDTH HOOD HORIZONTAL DISCHARGE 1415⁄16” 1715⁄16” CL 25⁄16” 43⁄16” 8” DIA. 33⁄16” 12¾” 9¾” OR 30” WIDTH HOOD 36” WIDTH HOOD HK0117A 81⁄16” 1415⁄16” 1715⁄16” HK0122A 3. REMOVE GREASE FILTERS 2 Rest the range hood on a table. Remove tape on filters.
5. BLOWER REMOVAL (HORIZONTAL DISCHARGE ONLY) The CC32I Series range hoods are factory shipped with the blower mounted for a vertical discharge configuration. For a horizontal discharge configuration, disassemble the blower from the inner top of the hood (see illustrations below). It will be assembled to the inner back of the hood once the hood is mounted on the wall. Unplug the blower.
. WIRING INSTALLATION ! WARNING Improper grounding can result in a risk of electric shock. Consult a qualified electrician if the grounding instructions are not completely understood, or if doubt exists as to whether the appliance is properly grounded. Do not use an extension cord. If the power supply cord is too short, have a qualified electrician install an outlet near the appliance, in accordance with all applicable codes and standards. Turn off electrical power at service entrance before wiring.
. INSTALL HOOD MOUNTING BRACKET ! WARNING WALL STUDS When cutting or drilling into wall, do not damage electrical wiring and other hidden utilities. Construct wood wall framing that is flush with surface of wall studs. Wood wall framing must be at least 1/2” thick and 3” high. Ensure to assemble wood wall framing to wall studs for a solid installation. Make sure the height of the framing will allow the mounting bracket to be secured to the framing within the dimensions shown (see illustration beside).
11. REINSTALL BLOWER (HORIZONTAL DISCHARGE ONLY) A Position the blower on the higher (A) or lower (B) back wall discharge as determined previously. Using a 5/16” socket, or a Robertson or a Phillips no. 2 screwdriver and the 4 previously removed screws, secure the blower to the hood. NOTE: In order to ease installation, before mounting the blower, prepare the screw holes by screwing all 4 screws without the blower, then remove and mount the blower.
13. INSTALL 8” ADAPTER/DAMPER (VERTICAL DISCHARGE AND NON-DUCTED INSTALLATION ONLY) Mount the 8” round adapter/damper (included in a separate box) to the hood using 4 no. 8 x 3/8” sheet metal screws (included). HJ0038 14. DUCT CONNECTION (VERTICAL DISCHARGE AND NON-DUCTED INSTALLATION ONLY) VERTICAL DISCHAGE: Plug hood power cord into the outlet. Slide a 8” metal round duct over the adapter/damper on the hood. Use metal foil duct tape to seal the joint.
15. PREPARE DECORATIVE FLUE (ALL INSTALLATIONS) DUCTED INSTALLATION: LOUVERS Remove protective plastic film covering the lower flue only. Peel off both corners at the top of the upper flue. Position the lower flue rear notches down (the ones with the 45° angle). Gently slide upper flue inside lower flue, louvers end first (so that louvers are hidden inside lower flue, as they are not needed for the ducted installation).
16. INSTALL DECORATIVE FLUE (ALL INSTALLATIONS) (CONT'D) UPPER FLUE MOUNTING BRACKET FRONT VIEW DUCTED INSTALLATION: Slide up the upper flue until it is aligned with its mounting bracket. The bracket must be UPPER inside the flue. Secure the upper flue to its bracket using 2 no. 8 x 3/8” screws (included). FLUE See illustration beside. NOTE: Duct not shown in illustration to ease understanding. HO0140 NON-DUCTED INSTALLATION: Slide the upper flue up to the ceiling. The plenum must be inside the flue.
18. REINSTALL GREASE FILTERS Using a Phillips no. 2 screwdriver, assemble the knob to each filter. The screw MUST BE on same end than filter tabs. See illustration beside. HO0139 Rest rear filters edge on filter springs in the range hood. Using knob, tilt up the filters into position. Make sure filter tabs (A) are securely engaged in range hood front edge after installation. HD0392 A 19. LIGHT BULBS This hood requires shielded halogen lamps (120 V, 50 W, PAR16 with GU10 base), included.
20. CARE (CONT'D) Hood cleaning Do: Don’t: • Regularly wash with clean cloth or rag soaked with warm water and mild soap or liquid dish detergent. • Use any steel or stainless steel wool or any other scrapers to remove stubborn dirt. • Always clean in the direction of original polish lines. • Use any harsh or abrasive cleansers. • Always rinse well with clear water (2 or 3 times) after cleaning. Wipe dry completely. • Allow dirt to accumulate.
22. WIRING DIAGRAM J2 Lamp T1 J1 YEL J8 WHT WHT 1 2 3 YEL RED Lamp BLK BLK J4 WHT 1 2 3 YEL BLK WHT J9 J10 BLK WHT J5 WHT 5 GRN ORG BRN COLOR CODE BLK BLACK BLU BLUE BRN BROWN GRN GREEN GRY GREY ORG ORANGE RED RED WHT WHITE YEL YELLOW RED WHT M GRY WHT BLU 3 WHT BLK ORG 4 BLK 2 BLU 1 J6 1 2 3 4 5 J11 J15 1 2 120 VAC FAN SPEED AND LIGHT CONTROL BLU BLU J12 HE0110A 23.
24. SERVICE PARTS 1 KEY PART NO. DESCRIPTION NO.