Owner's Manual

2. Press and hold the Pair Button on the sensor
for 1 second, Fig. 2.
a. Upon release of the Pair Button the LED will flash twice.
b. The sensor will remain in its pairing state for 1 minute.
3. Move the sensor next to the VenNet thermostat to be
paired, within 3 inches of the thermostat.
4. The thermostat will recognize the sensor and display
NEW SENSOR IS DETECTED, fig 3.
Press WARMER to pair the sensor to the thermostat.
a. The thermostat will display PAIRING.
b. Pressing COOLER will remove the message from the
display and stop the pairing procedure on the thermostat.
5. Once pairing is completed you must select the type of
sensor; Remote or Outdoor.
a. At this point, the thermostat will display
REMOTE SENSOR TYPE,
press WARMER or COOLER to change,
press MODE to accept.
I. Pressing WARMER or COOLER will allow you to
choose REMOTE SENSOR or OUTDOOR SENSOR.
II. Press FAN to accept the type of sensor chosen.
III. The thermostat will display SENSOR # IS PAIRED
twice and return to the Home screen.
6. A logical name may be assigned to the sensor through
Skyport Cloud Services.
TO RESTORE THE FACTORY DEFAULT SETTINGS
TO THE SENSOR:
It may be necessary to reset the sensor if pairing to a new
thermostat. This will remove the previously paired thermostat
from the sensor’s memory.
1. Press and hold the sensor’s Pair Button for up to 5 seconds
to restore Factory Default Settings in the sensor.
a. Once the sensor is reset, the sensor’s LED will flash twice
and return to pairing mode.
b. If not paired to a thermostat upon entering pairing mode
the sensor will go to “sleep” in 1 minute.
fig. 3
fig. 2
PUSH TO PAIR
PUSH TO PAIR
NEW SENSOR