residential THERMOSTAT Digital Thermostat T1010 Single Day PROGRAMMABLE up to 2-heat & 2-cool HEAT COOL HEAT PUMP Control up to 2 Heat & 2 Cool Stages HP Stages: 2 Heat, 2 cool Single Day Programmable 4 Settings Per Day Auto Changeover 5 min.
Table Of Contents FRONT PANEL DISPLAY QUICK START Set the clock and go SELECTING THE HEAT OR COOL MODE BASIC OPERATION PROGRAMMING A DAILY SCHEDULE ADVANCED SETUP ABOUT ADVANCED FEATURES & OPERATION WARRANTY CAUTION Follow Installation Instructions carefully. DISCONNECT POWER TO THE HEATER AIR CONDITIONER BEFORE REMOVING THE OLD THERMOSTAT AND INSTALLING THE NEW THERMOSTAT. Venstar Inc.
Front Panel AUTO COOL 76 HEAT 68 Liquid Crystal Display with Thermoglow Up/Down Buttons Mode Button Fan Button Heat or Cool Indicator Red = Heat, Green = Cool Page 2
Display AUTO COOL 88 HEAT OFF Fan On 88 Mode Indicators - Page 5 Selects the operational mode of the equipment. HEAT - Indicates the heating mode. COOL - Indicates the air conditioning mode. AUTO - Indicates the system will automatically changeover between heat and cool modes as the temperature varies. AUTO (Program) - When program mode is entered the letters ( ) appear for two seconds and the Auto icon blinks continuously to indicate the time period program is enabled to run.
Quick Start Set the Clock and Go Press the MODE and FAN buttons at the same time for two seconds to enter Setup screens. MODE FAN Setting the Clock i2 00 a Hours Tip: To change hours quickly, press and hold the FAN button and press the UP or DOWN buttons. Press the MODE and FAN buttons at the same time to return to normal operation. During Setup & Programming: Pressing the UP or DOWN butt ons will modify th e flashing selection. am/pm Minutes To adjust the Clock use MODE FAN buttons.
Selecting the Heat or Cool Mode Select Mode by Pressing the MODE Button Heating Only The HEAT setting indicates the temperature the room has to reach before the furnace will turn on to heat the room. 72 74 HEAT Press MODE Cooling Only The COOL setting indicates the temperature the room has to reach before the air conditioner will turn on to cool the room. 72 COOL 72 Press MODE 72 72 AUTO Heating or Cooling AUTO will automatically select heat or cool based on room temperature demand.
Basic Operation Selecting Your Desired Temperature (adjusting the setpoints) AUTO MODE Pressing the UP or DOWN buttons in Auto mode will adjust both the heat and cool set temperatures simultaneously. Adjust the desired COOL AUTO set temperature with the 76 HEAT 68 buttons. HEAT OR COOL MODE Pressing the UP or DOWN buttons in Heat or Cool mode will adjust only the heat or cool set temperature. Adjust the desired COOL set temperature with the 76 buttons.
Programming a Daily Schedule MODE Press the MODE button. While holding MODE, press the UP button for two seconds to enter time period programming. NOTE: If the thermostat is configured for single setpoint operation, time period program operation will be unavailable. 6 00 a Adjust the start time for Morning. Adjust the cooling setpoint for Morning. (35 - 99 ) Adjust the heating setpoint for Morning.
Programming a Daily Schedule Adjust the start time for Day. 8 00 85 2 85 2 62 p 6 00 78 3 a Press MODE COOL Adjust the cooling setpoint for Day. (35 - 99 ) Press MODE COOL Adjust the heating setpoint for Day. (35 - 99 ) Adjust the start time for Evening. HEAT Press MODE Press MODE COOL Adjust the cooling setpoint for Evening.
Programming a Daily Schedule 3 70 p I0 00 82 4 82 4 62 COOL Adjust the heating setpoint for Evening. (35 - 99 ) Adjust the start time for Night. 78 HEAT Press MODE Press MODE COOL Adjust the cooling setpoint for Night. (35 - 99 ) Press MODE COOL Adjust the heating setpoint for Night. (35 - 99 ) HEAT Press MODE MODE After programming is complete, press the MODE and UP buttons at the same time for two seconds to leave the Setup screens.
Advanced Setup Press the MODE button. While holding Mode, press the FAN button for 10 seconds to enter Setup screens. MODE FAN NOTE: Each step # is located at the top right corner of the display for easy reference. i2 00 2 a Adjust the time of day clock. Tip: To change hours quickly, press and hold the FAN button in and press the UP or DOWN buttons.
Advanced Setup 4 On ON = Heat Pump operation OFF = Gas Electric operation Off hp OFF Press b O 0 Select the reversing valve polarity for Heat Pump operation: O = Energize in cooling b = Energize in heating 5 (Step 5 only appears if heat pump is on in step 4) MODE Press MODE 6 On Select Electric Heat operation: On = 1st stage electric heat Off = 1st stage gas heat Off (Step 6 only appears if heat pump is off in step 4) eh OFF Press MODE 2 Adjust the deadband for the 1st stage.
Advanced Setup Adjust the minimum difference between cooling & heating setpoints. (0 - 6 ) 2 COOL 8 HEAT (Step 8 only appears if dual setpoint is selected in step 2) Press 6 cy MODE 9 Select the cycles per hour limit: d=cycles per hour limit defeated d1=d + defeat 5 min.
Advanced Setup Advanced Setup Table Step # 1 2 3 4 5 6 7 8 9 10 11 Description Time of Day Display Mode Time Period Program Heat Pump Reversing Valve Polarity Electric Heat Deadband/Temp.
About Advanced Features & Operation CALIBRATION - Under normal circumstances it will not be necessary to adjust the calibration of the temperature. If calibration is required, please contact a trained HVAC technician to correctly perform the following procedure. MODE Press the MODE button once. The thermostat temperature will be displayed and may be calibrated using the UP or DOWN buttons. Place the thermostat in the OFF mode. 49 OFF MODE Press and hold the AUTO MODE button.
About Advanced Features & Operation Cooling Heating 2nd Stage turn on Deadband Deadband Deadband Deadband db 2 (non-adj. 2 ) db 1 (adj. 1-6 ) db 1 (adj. 1-6 ) db 2 (non-adj. 2 ) 1st Stage turn on DECREASE Heat Setpoint Cool Setpoint TEMPERATURE 1st Stage turn on 2nd Stage turn on INCREASE The above figure assumes the minimum on time for the prior stage has been met to allow the next stage to turn on, once the deadbands have been exceeded.
About Advanced Features & Operation FACTORY DEFAULTS - If, for any reason, you desire to return all the stored settings back to the factory default settings, follow the instructions below. WARNING: This will reset all Time Period and Advanced Programming to the default settings. Any information entered prior to this reset will be permanently lost. After all of the icons appear, release the MODE Place the therm- FAN MODE and DOWN ostat in the OFF mode. buttons.
About Advanced Features & Operation KEYPAD LOCKOUT - To prevent unauthorized use of the thermostat, the front panel buttons may be disabled. To disable, or ‘lock’ the keypad, press and hold the MODE button. While holding the MODE button, press the UP and DOWN buttons together. AUTO Press all three buttons in the order outlined above for keypad lockout COOL 76 HEAT MODE Fan On 68 To unlock the keypad, press and hold the MODE button. While holding the MODE button, press the UP and DOWN buttons together.
Warranty One-Year Warranty - This Product is warranted to be free from defects in material and workmanship.