Specifications

VP562/VP563
transition
centers outlet
over top of hood
BSLD/BHSLD LINER “H” in part number indicates halogen lighting. This model not available with heat
lamps.
WALL MOUNT LINER INSERT SPECIFICATIONS
*Exceeding recommended
mounting height may
compromise performance.
Connection Diagram (46 3/8” Width)
Connection Diagram (28 3/8” - 40 3/8” Widths)
600 CFM B200 Dual Blower
(Top View)
900 CFM B200 Dual & B100 Single Blower
(Top View)
300 CFM B100 Single Blower
(Top View)
Electrical
1 ¾”
Centerline
of Hood
8” Outlet
Vent
Holes
5 ¼”5 ½”
Wall Side
8” Outlet
6” Outlet
5 ¼”
Wall Side
Vent
Holes
Centerline
of Hood
Electrical (2)
5 ½”
7 ⁄”
1 ⁄”
7 ⁄”
1 ¾”
6” Outlet
Vent
Hole
3 ¼”
Electrical
Centerline
of Hood
Wall Side
1 ¾”
1 ⁄”5 ¼”
10” Round 10” Round
8” Round
17 ½”
2”
8” Round 6” Round
VP562 Transition (Optional) For B300
(B200 Dual Blower & B100 Single Blower)
U
L
CUS
R
36”
8’ Ceiling
24”-27”
12”
Custom
Enclosure
10 OR 12”
Round
Connection Diagram (28 3/8” - 46 3/8” Widths)
Recommended
Mounting Height*
28 ⁄”, 34 ⁄”, 40 ⁄”, 46 ⁄”
12”
19 ¼”
12”
6” LESS THAN
BOTTOM WIDTH
3”
BSLD/BHSLD
Electrical/Mechanical Specications For Blower Units
Model Volts Amps* Hz RPM
CFM
SP@0.0"
Equivalent CFM
CFM
SP@0.1"
CFM
SP@0.2"
CFM
SP@0.3"
Minimum Round
Duct Size
Sones
#
B100 Single 115 1.5 60 1550 300 450 273 245 225 6" (28 in.
2
) 5.4
B200 Dual 115 2.9 60 1550 600 900 531 480 430 8" (50 in.
2
) 6.5
B200 Dual & B100 Single 115 4.4 60 1550 900 1350 804 725 655 VP562: 10" (79 in.
2
) 6.3
* Add0.5ampforeachhalogenlight.Hoodsareavailablewithuorescentlight(oneforeachsingleordualblower)orwithhalogenlights(2lights:30"-41",3lights:42"-48").
• BecausetheMagicLung
®
blowerusescentrifugalltrationratherthanconventionalbafeormeshlters,theMagicLung
®
blowercanhandlecookingequipmentwithhighercubicfeetperminute(CFM)requirementsandcandeliverequivalentCFMmuchmore
efcientlythanotherthanotherltrationsystems.WhencomparingtheMagicLung
®
withotherblowerunitsmadebyothermanufacturers,usethe“EquivalentCFM”.
# RatingsinaccordancewiththeStandardTestCodebytheEnergySystemsLaboratoryoftheTexasEngineeringExperimentStation.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 0609A