Product Specifications

WALL MOUNT RANGE HOOD SPECIFICATIONS
CWEH9 Equipped with halogen lighting. These models not available with heat lamps. Shown with optional
duct cover(s) (sold separately). Optional duct covers are available in standard and custom sizes.
Connection Diagram (42”- 60” Widths)
Connection Diagram (48”- 66” Widths)
*Exceeding recommended
mounting height may
compromise performance.
300 CFM B100 Single Blower
(Top View)
600 CFM B200 Dual Blower
(Top View)
900 CFM B200 Dual & B100 Single Blower
(Top View)
1200 CFM Double B200 Dual Blowers
(Top View)
Connection Diagram (30”- 48” Widths) Connection Diagram (30”- 54” Widths) Recommended
Mounting Height*
Electrical/Mechanical Specications For Blower Units
Model Volts Amps* Hz RPM
CFM
SP@0.0"
Equivalent CFM
CFM
SP@0.1"
CFM
SP@0.2"
CFM
SP@0.3"
Minimum Round
Duct Size
Sones
#
B100 Single 115 1.5 60 1550 300 450 273 245 225 6" (28 in.
2
) 5.4
B200 Dual 115 2.9 60 1550 600 900 531 480 430 8" (50 in.
2
) 6.5
B200 Dual & B100 Single 115 4.4 60 1550 900 1350 804 725 655 VP562: 10" (79 in.
2
) 6.3
Two B200 Duals 115 5.8 60 1550 1200 1800 1062 960 860 VP563: 12" (113 in.
2
) 6.6
* Add 0.5 amp for each halogen light. Hood is available with halogen lights (2 lights: 30" - 41", 3 lights: 42" - 53", 4 lights: 54" - 66", +1 light for each 14" if over 66").
• BecausetheMagicLung
®
blowerusescentrifugalltrationratherthanconventionalbafeormeshlters,theMagicLung
®
blowercanhandlecookingequipmentwithhighercubicfeetperminute(CFM)requirementsandcandeliverequivalentCFMmuchmore
efcientlythanotherthanotherltrationsystems.WhencomparingtheMagicLung
®
withotherblowerunitsmadebyothermanufacturers,usethe“EquivalentCFM”.
# RatingsinaccordancewiththeStandardTestCodebytheEnergySystemsLaboratoryoftheTexasEngineeringExperimentStation.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 1009A
U
L
CUS
R
















6" Round


Motor
Cooling
Vent

Electrical



8" Round



Motor
Cooling
Vent
Electrical







8" Round
 
8" Round
Motor
Cooling
Vent
Electrical (2)
Space Between
Duct Covers
Model Width A
CWEH9-342 4"
CWEH9-348 8"
CWEH9-354 10"
CWEH9-360 12"
CWEH9-448 10"
CWEH9-454 10"
CWEH9-460 12"
CWEH9-466 14"
OPTIONAL
DUCT
COVER
OPTIONAL
DUCT
COVERS
Model Width A Width B
CWEH9-342 8" 8"
CWEH9-348 10" 10"
CWEH9-354 11" 11"
CWEH9-360 12" 12"
Model Width A Width B
CWEH9-448 11" 11"
CWEH9-454 11" 11"
CWEH9-460 12" 12"
CWEH9-466 13" 13"
Outlet Spacing for
900 CFM Models
Outlet Spacing for
1200 CFM Models