installation instructions

Page 5L113 0516A
Installation Details Continued
9) Raise the hood to its nal position and attach it to the load-bearing framework in the ceiling using appropriate hardware
or to the duct cover using the screws previously removed in Step 3.
10) From inside the hood, using UL listed wire nuts, attach the “neutral” wire(s) to the white lead(s), the “hot” wire(s) to
the black lead(s), and the ground wire(s) to the green lead(s).
Warning: Do not operate hood without proper ground connection.
11) Attach the transition to the blower deck assembly and seal with duct tape. The transition must t inside the exhaust
collar on the blower deck assembly. Reconnect the electrical connector(s). For assemblies with two connectors, connect
the right harness to the front connector and the left harness to the back connector. While taking care to properly align
the duct connection between the transition and the duct in the ceiling, reinstall the blower deck assembly into the
hood using the 12 screws previously removed in Step 7.
12) Replace the blower housings and the blower shields. Make sure that the dampers open and close smoothly.
13) Refer to Owner Maintenance Guide Operating Instructions for proper hood operation. Test all blower and light functions
to ensure they are operating properly.
Model Volts Amps Hz RPM
CFM
SP@0.0"
Equivalent CFM
CFM
SP@0.1"
CFM
SP@0.2"
CFM
SP@0.3"
Minimum Round
Duct Size
Sones
#
T200 Island Dual 115 4.0 60 1550 550 900 507 471 431 8" (50 in.
2
) 6.0
T400 Island Cluster 115 7.5 60 1550 1100 1800 998 855 774 12" (13 in.
2
) 6.4
• BecausetheMagicLung
®
blowerusescentrifugalltrationratherthanconventionalbafeormeshlters,theMagicLung
®
blowercanhandlecookingequipmentwithhighercubicfeetperminute(CFM)requirementsandcandeliverequivalentCFMmuchmore
efcientlythanotherltrationsystems.WhencomparingtheMagicLung
®
withotherblowerunitsmadebyothermanufacturers,usethe“EquivalentCFM”.
#
RatingsinaccordancewiththeStandardTestCodebytheEnergySystemsLaboratoryoftheTexasEngineeringExperimentStation.